Skip to main content

illumia®Plus2 Integrating Sphere Spectroradiometers

Product information "illumia®Plus2 Integrating Sphere Spectroradiometers"

350-1050 nm; Sphere Size 0.25-3 m; Measurement Geometry 2π, 4π; Performance 0.001-713,250 lm; Max. 4π DUT Size ~16.7-~200 cm; Max. 2π DUT Size ~10 cm-~39 cm

Labsphere’s illumia®Plus2 series integrating sphere spectroradiometers are flexible, modular light measurement solutions with centralized data management. From high bays to headlights and everything in between, Labsphere has designed an integrating sphere spectroradiometer for your application, offering flexibility to meet your most demanding light measurement requirements.

When a solid-state light engine is used in a luminaire or fixture, the thermal environment near the LEDs is altered by both the design and the application environment. Comprehensive knowledge of the thermal behavior of your luminaire’s or fixture’s photometric and colorimetric performance starts with the illumia® Plus2 elevated temperature spectroradiometers, enabling you to characterize the thermal behavior of your luminaire or fixture simply and confidently across a temperature range of +15°C to +80°C. These elevated temperature spectroradiometers include a choice of a 1.65 m or 2 m insulated integrating sphere with temperature-controlled feedback loop, application-specific modules, accredited reference lamps and Integral® Software.

Build a system that meets your needs: illumia®Plus2 integrating sphere spectroradiometers offer flexibility to meet your most demanding requirements and grow with your business. The systems are available in sizes from 25 cm to 3 m in both 2π and 4π geometries. Choose from three spectrometer options and application-specific electronic modules that help you maximize efficiency and productivity while maintaining high absolute accuracy and repeatability, no matter the application.

These systems’ advanced integrating sphere design yields improved productivity by allowing lamp “hot swap” to achieve greater efficiency and laboratory throughput. Add-on electronic modules increase functionality and simplify compliance with IES LM-79-19, IES LM-78, and equivalent measurement guidelines.

Labsphere’s illumia®Plus2 elevated temperature integrating sphere spectroradiometers are designed specifically to test photometric and colorimetric performance over a broad dynamic range of temperatures per IES LM-82 and LM-79-19 recommended practices.

Using Labsphere’s Integral® software, you can operate your system from any device at any location and in multiple languages or automate calibration routines with built in LM-45 stabilization. The software meets LM-79-19 and LM-78 measurement methods and industry standard color calculations.

Key Features:

  • Sphere Sizes from 25 cm to 3 m for your Device under Test
  • 2π and 4π Measurement Geometries
  • Three Spectrometer Options to Meet Your Spectral and Dynamic Range Needs
  • Control Module and Programmable Power Supplies Deliver Full Automation
  • Improved Productivity:
    - Add-on Electronic Modules Increase Functionality and Simplify Compliance
    - Automated Calibration Routines Ensure Ease-of-use and Improved Efficiency
    - Automated IES LM-79-19 Stabilization Routine
    - Improved Integrating Sphere Design Allowing Lamp “Hot Swap” to Achieve Greater Efficiency and Shorter Measurement Time
    - Generate Reports Using Excel Templates: Data Where You Want It, How You Want It, Formatted for Language and Style

  • Typical Lumen Ranges: From 0.001 lm to 3,400 lm all the way to 0.07 lm to 713,250 lm
  • Spectral Flux Measurement Wavelength Range: 350 nm to 1050 nm
  • Exposure Time Range: 40 µs to 900 s (Depends on Sphere Size and Source Type)
  • Typical Performances Across All Variants:
    - Tungsten Filament: 0.007 lm to 65,4750 lm
    - Cool White LED: 0.001 lm to 713,250 lm
    - Warm White LED: 0.001 lm to 675,000 lm
    - Blue LED: 0.001 lm to 38,250 lm
    - Red LED: 0.002 lm to 54,000 lm
  • Max. 4π DUT Sizes: ~16.7 cm Linear Lamps, ~2.5 cm Small Lamps to ~200 cm Linear Lamps, ~30 cm Diameter Small Lamps (ref. LM-78)
  • Max. 2π DUT Sizes: ~10 cm Diameter to ~39 cm Diameter (ref. LM-79)

Key Features illumia®Plus2 800:

  • Wide Spectral Range
  • Fast CMOS Array Detector
  • Compact Size
  • Ideal for QC and Manufacturing Applications
  • High Sensitivity

Key Features illumia®Plus2 2600:

  • Fast, Low-noise, TE-cooled Back–thinned CCD Array Detector
  • Shutter for Dark Measurements in Real-time
  • Hardware Triggering Capability
  • Exceptional Stability at Long Exposure Time
  • High Dynamic Range

Additional Key Features illumia®Plus2 Elevated Temperature:

  • Based on CDS 2600 Spectrometers
  • Ambient Temperature Control and Monitoring
  • Light Source Temperature Monitors
  • LIV and Temperature Stability

Key Features illumia®Plus2 3020/3030:

  • Exceptional Measurement Sensitivity
  • Inbuilt Filter Wheel With ND Filters Provides Excellent Dynamic Range
  • Low Stray Light
  • High Speed
  • Easily Synchronized With Other Devices

Applications: Measuring Packaged LEDs, Clustered LEDs, Miniature Lamps, Entertainment Lighting, Automotive Lighting, (LED) Troffers, (LED) Luminaires, Indoor Lighting, Outdoor Lighting, Roadway Lighting, Lamp and Luminaires, CFLs, Fluorescent Lamps, OLEDs, Low Power LEDs; HID Lamps; LED Devices in High-speed Production Environment

Manufacturer "Labsphere"
Labsphere is an internationally recognized photonics company located in central New Hampshire. Founded in 1979, it is now part of the Halma Group of companies. Labsphere's extensive product offering ranges from image sensor characterization systems, remote sensing systems and light metrology systems to reflectance reference targets and standards as well as reflectance materials and coatings. Labsphere provides innovative solutions for a wide range of applications including LED/SSL lighting, remote sensing, imager/consumer camera, automotive, defense and security, health and biomedical optics to both production and research environments. https://www.labsphere.com Countries of Representation Denmark, Finland, Iceland, Italy, Norway, Sweden
Related links of the manufacturer

Customers also viewed

(H)PMCIR Fiber Optic Circulators
Polarization Maintaining; 780 to 1060 nm; 3/4 Ports; Insertion Loss ≤1.2 to ≤2.0 dB; Fiber Type Panda PM  The high power PM circulator is characterized with low insertion loss, high extinction ratio, high isolation, high power handling, high return loss, excellent environmental stability and reliability. They are ideal for fiber laser and instrumentation applications. Applications: Fiber Laser; Fiber Sensor
Product number: SW10344
Manufacturer:

SMARTSens-D Digital UVC Irradiance Sensors
254, 265, 275 nm; Irradiance 20-20000 µW/cm²; Resolution 0.3 µW/cm²; SNR 104; Interface USB 2.0 Type C; Power Supply 5 VDC, 100 mA Labsphere’s calibrated SMARTSens-D digital UVC irradiance sensors enable real-time UVC dose monitoring for the validation of UVC surface disinfection. Easily access dosage information on demand using Labsphere’s SMARTSens-D software platform, or integrate the digital sensors as a component in your UVGI system software using the provided firmware and APIs as the basis for developing a dashboard for multiple devices and installs. Each sensor is available for either UVC or far UVC measurements and delivers unparalleled application flexibility and measurement accuracy with irradiance responsivity calibration options for Hg sources (for disinfection at 254 nm) and LED sources, including 265 nm and 275 nm LEDs. Labsphere’s SMARTSens-D digital UVC irradiance sensors are available with one to four SSD-UVC/UVCF-2M sensors per UVC-HESC-001/002 controller. Choose the number of sensors that best monitors the UVC dose in your UVGI system design. Labsphere’s SMARTSens-D integrated digital UVC sensors UVC-HISC-001/002 feature the controller integrated into the sensor package for simplified dose monitoring and are available as single sensors that can be used to monitor UVC irradiance and dose. Multiple sensors can be networked and monitored from a central location. Not sure where to place your sensors or how many sensors you need? AMS Technologies and Labsphere have you covered with the supplier’s comprehensive radiometric modeling service. For SMARTSens products, Labsphere offers modeling of an enclosed volume such as UV-C disinfection cabinet or enclosure, as well as modeled simulations of illumination in the enclosed environment under varying lighting conditions and geometric scenarios. As a result, we can assist in determining the best locations for integrating SMARTSens UVC irradiance and dose-meter sensors to validate disinfection cabinet performance, hotspots, cold spots, and optical radiation distribution and uniformity. The modeling package includes: A Zemax model and optical radiation distribution in the chamber for up to three different lighting scenarios. Correlation between irradiance at up to five specific locations within the chamber to sensors mounted on the wall of the chamber A complete report that includes all analysis, summaries, and recommendations Key Features: Real-time Dose Monitoring for Disinfection Confidence and Exposure Safety Instantaneous System Performance Feedback Enables Immediate Troubleshooting and Increased Performance Confidence Concurrent Dose Monitoring Allows Tracking of Area Safety Levels to Optimize Efficiencies Measures Surface Irradiance Irradiance Range: 20 µW/cm² to 20 mW/cm² Absolute Resolution: 0.3 µW/cm² Relative Resolution: 0.0015% to 1.5%, Depending on Irradiance Signal to Noise Ratio: 104 f2 Directional Response: <1.5% Communication Protocol: USB 2.0 Type C Hardware Sampling Rate: 10 Hz User Defined Running Average: Up to 25 Readings Sensor Input Optics Type: Diffuser Dome, 9 mm Diameter Power Supply: USB 2.0 Type C, 5 VDC, 100 mA Dimensions Controllers: 41 x 41 x 24 mm (SSC-1000), 42 x 42 x 36 mm (SSC-4000) Dimensions Irradiance Sensors SSC-UVC/UVCF: 28 x 28 x 13 mm Dimensions Integrated Irradiance Sensors UVC-HISC-001/002: 41 x 41 x 23 mm Applications: Real-time UVC Dose Monitoring in Medical Disinfection Enclosures, Disinfection Chambers, Rooms and Production Systems; Validation of UVC Surface Disinfection; Tracking Disinfectant Lamp Performance in HVAC Systems for UVGI Coil Maintenance
Product number: SW11785
Manufacturer: