illumia®Plus2 Integrating Sphere Spectroradiometers
Product information "illumia®Plus2 Integrating Sphere Spectroradiometers"
350-1050 nm; Sphere Size 0.25-3 m; Measurement Geometry 2π, 4π; Performance 0.001-713,250 lm; Max. 4π DUT Size ~16.7-~200 cm; Max. 2π DUT Size ~10 cm-~39 cm
Labsphere’s illumia®Plus2 series integrating sphere spectroradiometers are flexible, modular light measurement solutions with centralized data management. From high bays to headlights and everything in between, Labsphere has designed an integrating sphere spectroradiometer for your application, offering flexibility to meet your most demanding light measurement requirements.
When a solid-state light engine is used in a luminaire or fixture, the thermal environment near the LEDs is altered by both the design and the application environment. Comprehensive knowledge of the thermal behavior of your luminaire’s or fixture’s photometric and colorimetric performance starts with the illumia® Plus2 elevated temperature spectroradiometers, enabling you to characterize the thermal behavior of your luminaire or fixture simply and confidently across a temperature range of +15°C to +80°C. These elevated temperature spectroradiometers include a choice of a 1.65 m or 2 m insulated integrating sphere with temperature-controlled feedback loop, application-specific modules, accredited reference lamps and Integral® Software.
Build a system that meets your needs: illumia®Plus2 integrating sphere spectroradiometers offer flexibility to meet your most demanding requirements and grow with your business. The systems are available in sizes from 25 cm to 3 m in both 2π and 4π geometries. Choose from three spectrometer options and application-specific electronic modules that help you maximize efficiency and productivity while maintaining high absolute accuracy and repeatability, no matter the application.
These systems’ advanced integrating sphere design yields improved productivity by allowing lamp “hot swap” to achieve greater efficiency and laboratory throughput. Add-on electronic modules increase functionality and simplify compliance with IES LM-79-19, IES LM-78, and equivalent measurement guidelines.
Labsphere’s illumia®Plus2 elevated temperature integrating sphere spectroradiometers are designed specifically to test photometric and colorimetric performance over a broad dynamic range of temperatures per IES LM-82 and LM-79-19 recommended practices.
Using Labsphere’s Integral® software, you can operate your system from any device at any location and in multiple languages or automate calibration routines with built in LM-45 stabilization. The software meets LM-79-19 and LM-78 measurement methods and industry standard color calculations.
Key Features:
- Sphere Sizes from 25 cm to 3 m for your Device under Test
- 2π and 4π Measurement Geometries
- Three Spectrometer Options to Meet Your Spectral and Dynamic Range Needs
- Control Module and Programmable Power Supplies Deliver Full Automation
- Improved Productivity:
- Add-on Electronic Modules Increase Functionality and Simplify Compliance
- Automated Calibration Routines Ensure Ease-of-use and Improved Efficiency
- Automated IES LM-79-19 Stabilization Routine
- Improved Integrating Sphere Design Allowing Lamp “Hot Swap” to Achieve Greater Efficiency and Shorter Measurement Time
- Generate Reports Using Excel Templates: Data Where You Want It, How You Want It, Formatted for Language and Style - Typical Lumen Ranges: From 0.001 lm to 3,400 lm all the way to 0.07 lm to 713,250 lm
- Spectral Flux Measurement Wavelength Range: 350 nm to 1050 nm
- Exposure Time Range: 40 µs to 900 s (Depends on Sphere Size and Source Type)
- Typical Performances Across All Variants:
- Tungsten Filament: 0.007 lm to 65,4750 lm
- Cool White LED: 0.001 lm to 713,250 lm
- Warm White LED: 0.001 lm to 675,000 lm
- Blue LED: 0.001 lm to 38,250 lm
- Red LED: 0.002 lm to 54,000 lm
- Max. 4π DUT Sizes: ~16.7 cm Linear Lamps, ~2.5 cm Small Lamps to ~200 cm Linear Lamps, ~30 cm Diameter Small Lamps (ref. LM-78)
- Max. 2π DUT Sizes: ~10 cm Diameter to ~39 cm Diameter (ref. LM-79)
Key Features illumia®Plus2 800:
- Wide Spectral Range
- Fast CMOS Array Detector
- Compact Size
- Ideal for QC and Manufacturing Applications
- High Sensitivity
Key Features illumia®Plus2 2600:
- Fast, Low-noise, TE-cooled Back–thinned CCD Array Detector
- Shutter for Dark Measurements in Real-time
- Hardware Triggering Capability
- Exceptional Stability at Long Exposure Time
- High Dynamic Range
Additional Key Features illumia®Plus2 Elevated Temperature:
- Based on CDS 2600 Spectrometers
- Ambient Temperature Control and Monitoring
- Light Source Temperature Monitors
- LIV and Temperature Stability
Key Features illumia®Plus2 3020/3030:
- Exceptional Measurement Sensitivity
- Inbuilt Filter Wheel With ND Filters Provides Excellent Dynamic Range
- Low Stray Light
- High Speed
- Easily Synchronized With Other Devices
Applications: Measuring Packaged LEDs, Clustered LEDs, Miniature Lamps, Entertainment Lighting, Automotive Lighting, (LED) Troffers, (LED) Luminaires, Indoor Lighting, Outdoor Lighting, Roadway Lighting, Lamp and Luminaires, CFLs, Fluorescent Lamps, OLEDs, Low Power LEDs; HID Lamps; LED Devices in High-speed Production Environment