ILT750 Bili Light Meter Series
Product information "ILT750 Bili Light Meter Series"
Wavelength 420-520 nm; Band Irradiance Range .08 to 8000 µW/cm2/nm; Irradiance Range 3 to 300,000 µW/cm2; Current Range 1 nA to 1.65 uA
The ILT750 Bili Light Meter is available in two configurations:
- ILT750 Bili Light Meter – 470 nm
- ILT750 Bili454 Light Meter – 454 nm, direct substitute for the Ohmeda Light Meter
The ILT750 Bili Light Meter is a comprehensive solution for measuring light in neonatal jaundice treatment systems. This bilirubin light meter eliminates the need for manual recording and calculation of multiple measurements to obtain your irradiance value. Simply move the ILT750 detector over the blanket or under the light source and let the meter calculate for you.
Key features:
- Dual units with a wide sensitivity range: from .08 to 8000 µW/cm2/nm, and 3.0 to 300,000 µW/cm2
- User-friendly device
- 3-digit display resolution
- Peak response at 470 nm, aligning with the bilirubin action spectrum
- Calibration that is ISO/IEC 17025:2017 Accredited and NIST Traceable
- Sensor corrected for cosine for accurate spatial response
- Measures Band Irradiance (µW/cm2/nm) or Irradiance (W/cm2)
- Compatible with traditional and LED sources
- Suitable for bili blankets, pads, or overhead lamps
- Housing that is easy to clean
- Compact and ergonomic design that is easy to hold
- Powered by AA batteries
- Made in the USA
The ILT750-BILI454 Light Meter serves as a direct substitute for the Ohmeda light meter, designed to test both traditional and LED blue light sources from GE, which are used in the treatment of neonatal jaundice. The advanced capabilities of the ILT model remove the need for manual calculations or note-taking. Simply move the detector across the blanket or beneath the light source, and the meter will handle the calculations for you.
After rigorous design and testing, the ILT750-BILI454 meter can read within a few percentage points of the discontinued Ohmeda Biliblanket II Blue light meter. This meter is versatile and can be used not only on the blanket but also on all GE lighting systems, including:
- GE Giraffe Systems
- GE Lullaby Systems
- GE BiliSoft Systems
- Traditional GE Blue light systems
Key features:
- Measures within a few percentages of the discontinued Ohmeda meter
- Features a large, easy-to-read OLED display
- Calibrated at 454 nm using a GE LED light source
- Can verify and average irradiance values across the entire treatment area in less than a minute
- Calibration is ISO/IEC 17025:2017 Accredited and NIST Traceable
- Allows selection of units (µW/cm2/nm or W/cm2)
- Designed with an easy-to-hold, lightweight, and ergonomic design that’s easy to clean
- Custom filter matching is designed into the device
- Made in the USA
Applications: testing of GE traditional and LED blue light sources for treatment of infant jaundice