ILT960 Portable Mini Spectroradiometer Series
Product information "ILT960 Portable Mini Spectroradiometer Series"
Wavelenght 200 - 1050 nm; Focal Length 60 mm; Dynamic Rance 3450; CMOS Linear Image Sensor; Signal/Noise Ratio 330:1; Integration Time 0.2 ms - 1 min
The most cost-effective, fully integrated CMOS-based spectroradiometer family available with ISO17025 accredited calibration. The ILT960 is equally at home on the production floor as it is the laboratory, combining high performance, accuracy, ease-of-use, and a wide array of features all in a rugged, compact, portable design. The ILT960-UV is a compact, portable mini spectrometer used to measure both the light’s amplitude and wavelength, and provide calibrated spectral irradiance, or power measurements. The ILT960 kits are combined with high end optics for proper light collection, including diffusers for cosine correction, and integrating spheres for total flux.
Three standard configurations are available:
- ILT960-UV: 200 - 500 nm
- ILT960-VIS: 200 - 850 nm
- ILT960-BB: 230 - 1050 nm
All ILT960 spectrometers include both wavelength and optical NIST traceable - ISO17025 accredited calibrations, with certification and data files. Complimentary SpectrILight III software is included at no cost, and DLL’s are available upon request. The ILT960 spectroradiometer light measurement systems come in three models, each with configured optics kits. The ILT960-UV, the ILT960-VIS, and the ILT960-BB. All systems come standard with SpectrILight III software, 1 meter long fiber, input optic, tripod, hard storage case, and calibration.
Key features:
- NIST-Traceable/ISO17025 Accredited Calibration
- Detector: CMOS Linear Image Sensor
- Focal Length: 60 mm
- Dynamic Range: 3450
- Symmetrical Czerny-Turner
- Stray Light: <0.2%
- Signal/Noise: 330:1
- Integration Time: 0.2 ms - 1 min
- Data Transfer Speed: 16 bits, 2 MHz
- Trigger Compatible
- Synchronization Capability
- Temperature Range: 0 - 50°C
- Size (mm): 35.4 H x 86 W x 110 L
- Dynamic Dark Correction and Non-Linearity Calibration
- Wavelength Accuracy: ILT960-UV: ±0.21 nm; ILT960-VIS: ±0.3 nm; ILT960-BB: ±0.6 nm
- Radiometric Accuracy: 200nm - 350nm: ±20%*; 350nm - 400 nm: ±10%*; 400nm - 900nm: ±5%; 900nm - 1050nm: ±10%
* Requires dual source calibration upgrade to assure radiometric accuracy in the UV
Applications: Plant Growth/PAR/Plant Photobiology, Characterization of Solar Simulation, Characterization of UV Curing Systems, Photostability Testing, Accelerated Weathering, Radiometery and Photometry Measurements, LED Illumination and Color Analysis, Absorbance/Transmittance, Reflectance, Fluorescence