Products
- Thermal Management
- Optical Technologies
- Electronics
- Chemicals
-
Suppliers
- 3SAE
- AdvR
- Altronic Research
- AMS Technologies
- Avantes
- BaySpec
- Blue Sky Research
- BWT Beijing
- CADDOCK Electronics
- Chroma Technology
- Chromacity
- Comair Rotron
- Connected Fibers
- Corning
- Cynergy 3 Components-Sensata Technologies
- Data-Pixel
- Digital Lightwave
- Duma Optronics
- Eblana Photonics
- Edinburgh Instruments
- Elforlight
- Elmeko
- Embraco
- Energy Pulse Systems
- EPIGAP Optronic
- Exalos
- Excelitas Technologies
- Fiber Instrument Sales
- Fiber Optic Center
- Fiberguide Industries
- Fibotec Fiberoptics GmbH
- FLAMMASSTEK
- FORC Photonics
- General Atomics
- General Photonics
- GH Optics
- Gooch & Housego
- High Energy Corporation
- Interfiber Analysis
- International Light Technologies
- Jennings Technology
- Jonard Tools
- KIMBERLY-CLARK
- Kimmon Koha Co.
- Kingfisher
- Koolance
- KrellTech
- Kryotherm
- II-VI Incorporated
- Labsphere
- Leclanché
- LightComm Technology
- LIGHTEL
- LightMachinery
- Litilit
- Lordan
- Luciol Instruments
- Luna
- Luxinar
- Lytron-Aavid-Boyd
- Maiman Electronics
- Magnelab
- MeccAl
- Mightex
- Musashi Engineering
- MWTechnologies
- Nanolap
- Nanometer Technologies
- Neltec
- neoLASE
- New England Photoconductor
- New Infrared Technologies (NIT)
- Noren
- Norland
- NorthLab
- NTT-AT
- NWL-Cornell Dubilier CDE
- OPTAplus BG
- OpTek Systems
- OptiGrate
- Optiphase
- Optoplast
- OSI LaserDiode
- OSI Optoelectronics
- Oven Industries
- Oxford Fiber
- OZ Optics
- PCO Excelitas
- Phenix Fiber Optics
- PROTECT-Laserschutz
- Pure Photonics
- Purex International
- QPC Lasers
- RAYLASE
- Samsung
- SDS High Voltage
- Sensuron
- Sercalo Microtechnology
- Sheetak
- Siskiyou
- SmarTThermoelectrics
- Solid State Cooling Systems
- Teem Photonics
- TELONIX
- Termotek AG
- TOPTICA eagleyard
- Toray Industries
- Trinamix
- Univet
- USHIO OPTO SEMICONDUCTORS
- UWAVE
- VIAVI Solutions
- Vigo System
- Vortex
- VWR
- Wavelength Electronics
- Webra
- Wooriro
-
XP Glassman
- X-Scan Imaging
- Solutions
- Company
- Blog
- Career
- Events
- Contact us
XP Glassman offers a solution to most high voltage DC power supply requirements thanks to a very large standard range of high voltage power supplies and to the capability to develop and manufacture custom HV power supplies. Standard power supplies include output voltages up to 500 kVDC with output power ratings up to 200 kW, all with our 3 year warranty.
XP Glassman’s DC power supplies are utilized for a broad range of applications in commercial, defence and research markets.
EJ Series High Voltage AC/DC Power Supplies
Input Voltage 102-264 VAC; Max. Output Voltage 1-60 kVDC; Max. Power 600 W; Efficiency >85%; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s EJ Series of 600 W high voltage AC/DC power supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response, 2U rack-mount units with tight regulation and extremely low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 60 kVDC.
The EJ series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The EJ Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.03% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. Front-panel digital encoders provide high-resolution local adjustment of voltage and current program. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor.
The EJ Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the EJ Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable.
The EJ Series supplies with 230 VAC input option (198 to 264 VAC RMS, 48 to 63 Hz) are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
2U Rack Mount
Air Insulated
Maximum Output Power: 600 W
Maximum Output Voltage: 1 to 60 kVDC
Maximum Output Current: 10 to 600 mA
Low Ripple: <0.03% of Rated Voltage + 0.5 V RMS at Full Load
Tight Regulation
Static Voltage Regulation: <0.005% for Specified Line and Load Variations
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 102 to 132, 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Rated Voltage
Maximum Stored Energy: 0.4 to 4.0 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status, Fault Status, +10 V Reference, I/V Mode Status
Options: 100, 230 VAC Input, Blank Front Panel, Zero Start Interlock, 0 to 5 V Voltage & Current Program/Monitor, Arc Count and/or Quench, Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 88.1 x 482.6 x 520.7 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11411
Manufacturer:
XP Glassman
ET Series High Voltage AC/DC Power Supplies
Input Voltage 198-264 VAC; Max. Output Voltage 1-60 kVDC; Max. Power 2,000 W; Efficiency >85%; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s ET Series of 2000 W high voltage AC/DC power supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response, 2U rack-mount units with tight regulation and extremely low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 60 kVDC.
ET series power supplies feature “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The ET Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.025% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. Front-panel digital encoders provide high-resolution local adjustment of voltage and current program. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor.
The ET Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the ET Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable.
The ET Series supplies are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
2U Rack Mount
Air Insulated
Maximum Output Power: 2000 W
Maximum Output Voltage: 1 to 60 kVDC
Maximum Output Current: 33 to 2000 mA
Low Ripple: <0.025% of Rated Voltage + 1 V RMS at Full Load
Tight Regulation
Static Voltage Regulation: <0.005% for Specified Line and Load Variations
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Rated Voltage
Maximum Stored Energy: 1.0 to 6.2 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status, Fault Status, +10 V Reference, I/V Mode Status
Options: Blank Front Panel, Zero Start Interlock, 0 to 5 V Voltage & Current Program/Monitor, Arc Count and/or Quench, Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 88.1 x 482.6 x 558.8 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11412
Manufacturer:
XP Glassman
EV Series High Voltage AC/DC Power Supplies
Input Voltage 198-264 VAC; Max. Output Voltage 0.75-1.5 kVDC; Max. Power 3,000 W; Efficiency 85%; Voltage Regulation 0.01%; Current Regulation <0.02% + 4 mA
XP Glassman’s EV Series are sophisticated 3 kW high voltage AC/DC power supplies with low ripple and noise. They are air insulated, fast response, 2U rack-mount units with tight regulation. A range of models is available with output voltage ranges from 0 to 750 VDC through 0 to 1.5 kVDC.
The EV series features active power factor correction (PFC) over the single-phase input voltage range of 198 to 264 VAC. Either terminal of the floating output may be grounded for operation as a positive or negative supply. Up to four identical supplies may be operated in parallel with user-configurable master and active current sharing. EV Series 2U rack-mount supplies may be stacked with no space required between supplies.
Front panel digital encoders provide high-resolution local adjustment of voltage and current program. A remote analog interface enables user selectable 0 to 5 V or 0 to 10 V analog programming. Integral RS-232, RS-485, USB and optional Ethernet communications provide remote control program and monitor with 12 bit accuracy. A rear panel switch allows selection of either constant-current or current-trip operation. The unit stores power supply parameters at each AC turn-off sequence.
Ripple is less than 0.1% RMS of rated voltage at full load up to 1 MHz. Total ripple and noise is less than 0.4% peak-to-peak of rated voltage up to 20 MHz. The EV Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. Forced air cooling with high-speed frictionless bearing technology fans reduces noise and extends fan life.
Standard accessories for the EV Series include a line cord, null modem cable, RS485 daisy chain cable and USB cable.
The EV Series supplies are fully compliant with the following European directives:
EN61010-1/IEC61010-1, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
2U Rack Mount
Floating Output with 1,500 V Isolation
Maximum Output Power: 3 kW
Maximum Output Voltage: 750 to 1,500 VDC
Maximum Output Current: 2.0 to 4.0 A
Low Ripple: <0.1% RMS of Rated Voltage (10 Hz to 1 MHz)
Maximum Ripple and Noise: 3 to 6 V (Peak-to-Peak up to 20 MHz)
Static Voltage Regulation: <0.01% for Specified Line and 0.1% for Specified Load Variations
Current Regulation: <0.02% + 4 mA From Short Circuit (>1 mΩ) to Rated Voltage
Constant Voltage/Constant Current Operation
Field Strappable Parallel Operation: Up to 4 Identical Units Can Be Connected in Parallel
Front Panel, Remote, RS232, RS485, USB & Optional Ethernet Control
Input Voltage: 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: 85% Typical at Full Load
Power Factor: 0.99 Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Stored Energy: 5 to 11.3 J
Voltage Monitor: 0 to +5/+10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +5/+10 VDC Signal for 0 to Rated Current
Stability: 0.05% Over 8 h After 0.5 h Warm-up
Polarity: Floating Output, Either Output can be Connected to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Options: Arc Quench, Arc Count, Latching Arc Count, Ethernet, Slow Start Ramp
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 88.1 x 482.6 x 508.0 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11416
Manufacturer:
XP Glassman
EY Series High Voltage AC/DC Power Supplies
Input Voltage 198-264 VAC; Max. Output Voltage 1-60 kVDC; Max. Power 1,200 W; Efficiency >85%; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s EY Series of 1200 W high voltage AC/DC power supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response, 2U rack-mount units with tight regulation and extremely low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 60 kVDC.
The EY series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The EY Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.02% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. Front-panel digital encoders provide high-resolution local adjustment of voltage and current program. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor.
The EY Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the EY Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable.
The EY Series supplies are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
2U Rack Mount
Maximum Output Power: 1200 W
Maximum Output Voltage: 1 to 60 kVDC
Maximum Output Current: 20 to 1200 mA
Low Ripple: <0.02% of Rated Voltage + 0.5 V RMS at Full Load
Tight Regulation
Static Voltage Regulation: <0.005% for Specified Line and Load Variations
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Rated Voltage
Maximum Stored Energy: 1.0 to 4.1 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status, Fault Status, +10 V Reference, I/V Mode Status
Options: Blank Front Panel, Zero Start Interlock, 0 to 5 V Voltage & Current Program/Monitor, Arc Count and/or Quench, Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010; EN61010; 2011/65/EU, Restrictions of the use of hazardous substances (RoHS); EN61000-6-4 EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 85.7 x 431.8 x 520.7 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11413
Manufacturer:
XP Glassman
FJ Series High Voltage AC/DC Power Supplies
Input Voltage 102-264 VAC; Max. Output Voltage 1-60 kVDC; Max. Power 120 W; Efficiency >85%; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s FJ Series of 120 W high voltage AC/DC power supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response, 1U rack-mount units with tight regulation and extremely low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 60 kVDC.
The FJ series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The FJ Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.02% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. Front-panel digital encoders provide high-resolution local adjustment of voltage and current program. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor.
The FJ Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the FJ Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable.
The FJ Series supplies with 230 VAC input option (198 to 264 VAC RMS, 48 to 63 Hz) are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
1U Rack Mount
Air Insulated
Maximum Output Power: 120 W
Maximum Output Voltage: 1 to 60 kVDC
Maximum Output Current: 2 to 120 mA
Low Ripple: <0.02% of Rated Voltage + 0.5 V RMS at Full Load
Tight Regulation
Static Voltage Regulation: <0.005% for Specified Line and Load Variations
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 102 to 132, 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Rated Voltage
Maximum Stored Energy: 0.2 to 2.4 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status, Fault Status, +10 V Reference, I/V Mode Status
Options: 100, 230 VAC Input, Blank Front Panel, Zero Start Interlock, 0 to 5 V Voltage & Current Program/Monitor, Arc Count and/or Quench, Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 43.6 x 482.6 x 508.0 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11408
Manufacturer:
XP Glassman
FL Series High Voltage AC/DC Power Supplies
Input Voltage 90-264 VAC; Max. Output Voltage 750-1,500 VDC; Max. Power 1.5 kW; Efficiency 84%; Voltage Regulation <0.05%; Current Regulation <0.02% of Rating + 4 mA
XP Glassman’s FL Series are sophisticated 1.5 kW high voltage AC/DC power supplies with low ripple and noise. They are air insulated, fast response, 1U rack-mount units with tight regulation. A range of models is available with output voltage ranges from 0 to750 VDC through 0 to 1,500 VDC.
The FL Series features a universal voltage input with continuous operation over the single-phase input voltage range of 90 to 264 VAC, with active power factor correction (PFC). Either terminal of the floating output may be grounded for operation as a positive or negative supply. Up to four identical supplies may be operated in parallel with user-configurable master and active current sharing. FL Series 1U rack-mount supplies may be stacked with no space required between supplies.
Front panel digital encoders provide high-resolution local adjustment of voltage and current program. A remote analog interface enables user selectable 0 to 5 V or 0 to 10 V analog programming. Integral RS-232, RS-485, USB and optional Ethernet communications provide remote control program and monitor with 12 bit accuracy. A rear panel switch allows selection of either constant-current or current-trip operation.
Ripple is less than 0.05% RMS of rated voltage at full load up to 1 MHz. Total ripple and noise is less than 0.2% peak-to-peak of rated voltage up to 20 MHz. The FL Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. Fan speed control is adjusted automatically as a function of operating temperature. This reduces noise and extends fan life.
Standard accessories for the FL Series include null modem cable, RS485 daisy chain cable and USB cable.
The FL Series supplies are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010-1/IEC61010-1, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
1U Rack Mount
Floating Output with 1,500 V Isolation
Maximum Output Power: 1,500 W
Maximum Output Voltage: 750 to 1,500 VDC
Maximum Output Current: 1.0 to 2.0 A
Low Ripple: <0.05% RMS of Rated Voltage (10 Hz to 1 MHz)
Maximum Ripple and Noise: 1.5 to 3 V (Peak-to-Peak)
Static Voltage Regulation: <0.01% for Specified Line and 0.05% for Specified Load Variations
Current Regulation: <0.02% of the Rating + 4 mA, From Short Circuit to Rated Voltage
Constant Voltage/Constant Current Operation
Field Strappable Parallel Operation: Up to 4 Identical Units Can Be Connected in Parallel
Front Panel, Remote, RS232, RS485, USB & Optional Ethernet Control
Universal Input – Input Voltage: 90 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: 84% Typical at Full Load
Power Factor: 0.99 Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Stored Energy: 2.80 to 6.75 J
Voltage Monitor: 0 to +5/+10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +5/+10 VDC Signal for 0 to Rated Current
Stability: 0.05% Over 8 h After 0.5 h Warm-up
Polarity: Floating Output, Either Output can be Connected to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Options: Arc Quench, Arc Count, Ethernet, Slow Start Ramp
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 43.6 x 482.6 x 508.0 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11423
Manufacturer:
XP Glassman
FR Series High Voltage AC/DC Power Supplies
Input Voltage 102-264 VAC; Max. Output Voltage 1-60 kVDC; Max. Power 300 W; Efficiency >85%; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s FR Series of 300 W high voltage AC/DC power supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response, 1U rack-mount units with tight regulation and extremely low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 60 kVDC.
The FR series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The FR Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.025% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. Front-panel digital encoders provide high-resolution local adjustment of voltage and current program. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor.
The FR Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the FR Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable.
The FR Series supplies with 230 VAC input option (198 to 264 VAC RMS, 48 to 63 Hz) are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
1U Rack Mount
Air Insulated
Maximum Output Power: 600 W
Maximum Output Voltage: 1 to 60 kVDC
Maximum Output Current: 5 to 300 mA
Low Ripple: <0.025% of Rated Voltage + 0.5 V RMS at Full Load
Tight Regulation
Static Voltage Regulation: <0.005% for Specified Line and Load Variations
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 102 to 132, 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Rated Voltage
Maximum Stored Energy: 0.35 to 3.5 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status, Fault Status, +10 V Reference, I/V Mode Status
Options: 100, 230 VAC Input, Blank Front Panel, Zero Start Interlock, 0 to 5 V Voltage & Current Program/Monitor, Arc Count and/or Quench, Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 43.6 x 482.6 x 508.0 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11409
Manufacturer:
XP Glassman
GX Series High Voltage AC/DC Power Supplies
Input Voltage 342-528 VAC 3-Phase; Max. Output Voltage 1-100 kVDC; Max. Power 25,000 W; Efficiency >80%; Voltage Regulation <0.01%; Current Regulation <0.5%
XP Glassman’s GX Series are sophisticated 25 kW high voltage AC/DC power supplies with low ripple and noise. They are air insulated, fast response, 11U rack-mount units with tight regulation. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 100 kVDC. Up to eight GX Series power supplies can be connected in parallel, providing up to 200 kW output power and active current sharing with dedicated master-slave configuration.
Air is the GX Series’ prime dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset time interval. The GX Series’ high voltage output is inhibited for a short period after each load arc to quickly extinguish the arc.
Typically, ripple is less than 0.1% RMS of rated voltage at full load. The microcontroller-based front panel control and communication interface provides high-resolution voltage and current programming with either front panel digital encoders, analog remote interface or integral RS232/USB serial ports and optional Ethernet interface. The unit stores power supply parameters at each AC turn-off sequence.
The GX Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. The GX Series also features a forced air, enhanced reliability system with redundant thermal overload protection including temperature sensing and fan speed monitor.
Standard accessories for the GX Series include a remote interface mating connector, a detachable 2,4 m shielded high voltage coaxial output cable, null modem and USB cable as well as all chassis interconnect cables.
The GX Series supplies are fully compliant with the following European directives:
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
11U Rack Mount
Maximum Output Power: 25 kW – Parallelable to 200 kW
Maximum Output Voltage: 1 to 100 kVDC
Maximum Output Current: 0.250 to 25.0 A
Low Ripple: <0.1% of Rated Voltage + 1 V RMS at Full Load
Tight Regulation
Static Voltage Regulation: <±0.01% of Rating for Specified Line and Load Variations
Current Regulation: <0.5% of Rating From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 380, 415, 480 VAC RMS ±10% , 48 to 63 Hz, Three Phase
Efficiency: >80% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Stored Energy: 12 to 69 J
Voltage Monitor: 0 to +10/+5 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10/+5 VDC Signal for 0 to Rated Current
Stability: 0.05% of Rated Over 8 h After 0.5 h Warm-up
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Current Limit, Current Trip, Over-temperature, Input Under-voltage, DC Under-voltage, Power Block Desaturation, Arc Count, Arc Quench
Signals Provided on the Remote Interface Connector: Voltage & Current Program/Monitor, HV On/Enable/Status, Safety Interlock, Fault Status
Options: Zero Start Interlock, Slow Start Ramp, Blank Front Panel, 0 to 5 V Voltage & Current Program/Monitor, Virtual RS-232 Com Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 487.4 x 482.6 x 609.6 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11424
Manufacturer:
XP Glassman
KR Series High Voltage AC/DC Power Supplies
Input Voltage 187-264 VAC; Max. Output Voltage 2-100 kVDC; Max. Power 3,000 W; Efficiency >85%; Voltage Regulation <0.005%; Current Regulation <0.1%, <0.2%
XP Glassman’s KR Series of 3 kW high voltage AC/DC power supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response, 4U rack-mount units with tight regulation and extremely low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 2 kVDC through 0 to 100 kVDC.
The KR series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The KR Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.05% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. Front-panel digital encoders provide high-resolution local adjustment of voltage and current program. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor.
The KR Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the KR Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable.
The KR Series supplies are fully compliant with the following European directives:
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
4U Rack Mount
Air Insulated
Maximum Output Power: 3 kW
Maximum Output Voltage: 2 to 100 kVDC
Maximum Output Current: 30 mA to 1.5 A
Low Ripple: <0.1% RMS of Rated Voltage (10 Hz to 1 MHz)
Tight Regulation
Static Voltage Regulation: <0.005% for Specified Line and 0.01% + 0.5 mV/mA for Specified Load Variations
Current Regulation: <0.1% (8 to 100 kV), <0.2% (2 to 6 kV) From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 187 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Rated Voltage
Maximum Stored Energy: 1.5 to 20.5 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive, Negative or Reversible Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status, Fault Status, +10 V Reference, I/V Mode Status
Options: Blank Front Panel, Zero Start Interlock, 0 to 5 V Voltage & Current Program/Monitor, Arc Count and/or Quench, Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 177.0 x 482.6 x 609.6 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11417
Manufacturer:
XP Glassman
KT Series High Voltage AC/DC Power Supplies
Input Voltage 198-264 VAC; Max. Output Voltage 70-150 kVDC; Max. Power 2,000 W; Efficiency >85%; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s KT Series of 2000 W high voltage AC/DC power supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response, 4U rack-mount units with tight regulation and low arc discharge currents. A range of models is available with output voltage ranges from 0 to 70 kVDC through 0 to 150 kVDC.
The KT series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The KT Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.025% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. Front-panel digital encoders provide high-resolution local adjustment of voltage and current program. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor.
The KT Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the KT Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable.
The KT Series supplies are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
4U Rack Mount
Air Insulated
Maximum Output Power: 2000 W
Maximum Output Voltage: 70 to 150 kVDC
Maximum Output Current: 10 to 29 mA
Low Ripple: <0.025% of Rated Voltage at Full Load
Tight Regulation
Static Voltage Regulation: <0.005% for Specified Line and 0.01% for Specified Load Variations
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Rated Voltage
Maximum Stored Energy: 11 to 20 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status, Fault Status, +10 V Reference, I/V Mode Status
Options: Blank Front Panel, Zero Start Interlock, 0 to 5 V Voltage & Current Program/Monitor, Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 177.0 x 482.6 x 609.6 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11414
Manufacturer:
XP Glassman
LH Open Stack Series High Voltage AC/DC Power Supplies
Input Voltage 187-460 VAC 3-Phase; Max. Output Voltage 200-500 kVDC; Max. Power 4,000, 8,000 W; Efficiency 80%; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s LH Open Stack Series of high voltage AC/DC power supplies are sophisticated 4 or 8 kW open stack power supplies with extremely low ripple and noise. They are air insulated fast response units with tight regulation. A range of models is available with output voltage ranges from 0 to 200 kVDC through 0 to 500 kVDC. One master supply and up to 4 slave supplies can be run in parallel, providing a maximum of 12 to 20 kW depending on the maximum DC voltage.
LH Open Stack series power supplies consist of a rack-style driver chassis, a high voltage stack assembly and a remote-control unit. The dimensions of the stack vary with the output voltage rating and are given in the specifications in the downloadable datasheet. The driver chassis is provided in a cabinet with 231.1 mm height x 636.5 mm depth. The remote-control unit size is 132.5 mm height x 482.6 mm width x 168.3 mm depth.
The LH Open Stack Series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The LH Open Stack Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.1% peak-to-peak of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. The LH Open Stack Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A current-trip feature may be substituted for constant-current operation by a remote-control chassis rear panel selector switch.
Standard accessories for the LH Open Stack Series include 7.6 m of detachable interconnect cables, null modem cable and USB cable.
The LH Open Stack Series supplies, when configured with the 400 VAC input option, are fully compliant with the following European directives:
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
Open Stack High Voltage
Air Insulated
Maximum Output Power: 4, 8 kW – Parallelable to 20 kW
Maximum Output Voltage: 200 to 500 kVDC
Maximum Output Current: 5 to 40 mA
Low Ripple: 100 to 160 Vpp High Frequency Ripple, 20 Vpp Line Frequency Ripple
Tight Regulation
Voltage Regulation: <0.005% for Specified Line and Load Variations
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 180 to 220 or 340 to 460 VAC RMS, 48 to 63 Hz, Three Phase
Efficiency: 80% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Setting
Maximum Stored Energy: 109 to 528 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote User Interface Terminal Strip: Voltage & Current Program/Monitor, HV Enable/Status, External Interlock, Fault Status, +10 V Reference, I/V Mode Status
Options: Zero Start Interlock, Slow Start Ramp, 0 to 5 V Voltage & Current Program/Monitor, Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: See Downloadable Datasheet
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11419
Manufacturer:
XP Glassman
LH Series High Voltage AC/DC Power Supplies
Input Voltage 187-460 VAC 3-Phase; Max. Output Voltage 1-150 kVDC; Max. Power 5,000 W; Efficiency >85%; Voltage Regulation <0.005%-<0.025%; Current Regulation <0.2%, <0.5%
XP Glassman’s LH Series are sophisticated 5 kW high voltage AC/DC power supplies with low ripple and noise. They are air insulated, fast response, 6U rack-mount units with tight regulation. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 150 kVDC.
The LH Series features “air” as the primary dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The LH Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.05% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. The LH Series’ front panel contains all local control functions like AC power on/off, separate 10-turn controls to set voltage and current levels, HV voltage on and off/reset switches as well as LED indicators for high voltage on, output polarity, interlock, fault status or voltage/current regulating mode. Output levels are indicated by voltage and current digital meters.
All voltage and current programming and monitoring signals are coupled to the user interface by true differential amplifiers. This provides for the ability to return the program and monitor commons to ground or system common at the source. This arrangement isolates the return wires and eliminates errors due to unwanted return currents flowing in these connections.
The LH Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the LH Series include a remote interface mating connector and a detachable 2,4 m shielded high voltage coaxial output cable.
The LH Series supplies, when configures with the 400 VAC input option, are fully compliant with the following European harmonized EMI directives:
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
6U Rack Mount
Air Insulated
Maximum Output Power: 5 kW – Parallelable to 25 kW
Maximum Output Voltage: 1 to 150 kVDC
Maximum Output Current: 25 mA to 5.0 A
Low Ripple: <0.05% RMS of Rated Voltage at Full Load
Tight Regulation
Static Voltage Regulation: <0.005% for Specified Line and 0.01% for Specified Load Variations, 0.025% for 80 to 100 kVDC Models
Current Regulation: <0.2% (8 to 150 kV), <0.5% (1 to 6 kV) From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 187 to 228 or 340 to 460 VAC RMS, 48 to 63 Hz, Three Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Stored Energy: 3.5 to 58 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive, Negative or Reversible Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Differential Voltage & Current Program/Monitor, HV Enable/Status, Safety Interlock, Fault Status, +10 V Reference, I/V Mode Status
Options: Blank Front Panel, Zero Start Interlock, Slow Start Ramp, 0 to 5 V Voltage & Current Program/Monitor, Arc Count and Quench, Common to Ground Isolation, Control and Monitor via RS232, USB, Ethernet
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 265.9 x 482.6 x 609.6 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11418
Manufacturer:
XP Glassman
LQ Series High Voltage AC/DC Power Supplies
Input Voltage 180-530 VAC 3-Phase; Max. Output Voltage 1-12 kVDC; Max. Power 10,000, 20,000 W; Efficiency >85%; Voltage Regulation <0.05%; Current Regulation <0.5%
XP Glassman’s LQ Series are sophisticated 10 or 20 kW high voltage AC/DC power supplies with low ripple and noise. They are air insulated, fast response, 5U rack-mount units with tight. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 12 kVDC. LQ power supplies can be paralleled, utilizing one master supply and up to four slave supplies for a maximum of 50 kW output power.
The LQ Series features “air” as the primary dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The LQ Series’ high voltage output is inhibited for a short period after each load arc to quickly extinguish the arc.
Typically, ripple is less than 0.1% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. The LQ Series’ front panel contains all local control functions like AC power on/off, separate 10-turn controls to set voltage and current levels, HV voltage on and off/reset switches as well as LED indicators for high voltage on, output polarity, interlock, fault status or voltage/current regulating mode. Output levels are indicated by voltage and current digital meters.
The LQ Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the LQ Series include a detachable 2,4 m shielded high voltage coaxial output cable and a 25-pin D-subminiature connector for customer interface.
The LQ Series supplies are fully compliant with the following European harmonized EMI directives:
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
5U Rack Mount
Air Insulated
Maximum Output Power: 10, 20 kW – Parallelable to 50 kW
Maximum Output Voltage: 1 to 12 kVDC
Maximum Output Current: 0.85 to 20 A
Low Ripple: <0.1% + 1 V RMS of Rated Output Voltage
Tight Regulation
Voltage Regulation: <±0.05% for Specified Line and Load Variations
Current Regulation: <0.5% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 180 to 220, 342 to 440, 370 to 460, 430 to 530 VAC RMS, 48 to 63 Hz, Three Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 1% of Setting + 0.5% of Rated
Output Voltage Repeatability: <0.1% of Setting
Stored Energy: 6 to 22 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable/Status, Fault Status, +10 V Reference, I/V Mode Status
Options: 0 to 5 V Voltage & Current Program/Monitor, Blank Front Panel, Slow Start Ramp, Zero Start Interlock, Control and Monitor via RS232, USB, Ethernet
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 221.5 x 482.6 x 609.6 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11421
Manufacturer:
XP Glassman
MJ Series High Voltage AC/DC Power Supplies
Input Voltage 105-250 VAC; Max. Output Voltage 3-30 kVDC; Max. Power 15 W; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s MJ Series of 15 W high voltage AC/DC power supplies are air-insulated, fast-response, chassis-mount units with tight regulation and low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 3 kVDC through 0 to 30 kVDC.
The MJ Series’ current regulation is unequalled in a module of this price range. For example, the regulation from short circuit to rated voltage for the 15 kV, 1 mA model is ±500 nA. Overload, short circuit and arc protection is provided by automatic current regulation and by careful surge limiting design. XP Glassman’s “Air Insulated” designs are completely serviceable, these modules are not epoxy block “throw-away” power supplies.
The MJ Series’ standard operation mode is constant voltage/current with less than 200 mJ of stored energy for most models. A “multi-mode” operation mode permits maximum user flexibility. Local voltage or current control is user selectable, and the MJ Series power supplies feature remote voltage and/or current control via 0 to +10 V signal or potentiometers. External interlock terminals allow enable/disable of the power supply via TTL signal.
Standard accessories for the MJ Series include a detachable 2,4 m shielded output cable and mating control connector.
The MJ Series supplies with 230 VAC input option (198 to 253 VAC RMS, 48 to 63 Hz) are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
Compact Module
Air Insulated
Low Ripple: <0.05% RMS of Rated Voltage at Full Load, ~0.01% at No Load
Tight Regulation
Static Voltage Regulation: <0.005%, Line and Load
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Maximum Output Power: 15 W
Maximum Output Voltage: 3 to 30 kVDC
Maximum Output Current: 0.4 to 5 mA
Input Voltage: 105 to 125, 210 to 250 VAC RMS, 48 to 63 Hz, Single Phase
Output Voltage Accuracy: 1% of Setting + 0.5% of Rated
Output Voltage Repeatability: <0.1% of Rated Voltage
Stored Energy: <200 mJ (15 kV Model), <400 mJ (30 kV Model)
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Remote Controls: DB25S D-Sub Connector and Mating Plug Provided for All Control Input Functions
Control Input Functions: +10 V Reference, External Interlock, Current Monitor, Current Program, Voltage Monitor, Voltage Program, TTL, Ground, Local Control
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +60 °C
Dimensions: 82.5 x 109.5 x 292.1/330.2 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11407
Manufacturer:
XP Glassman
MK Series High Voltage AC/DC Power Supplies
Input Voltage 90-253 VAC; Max. Output Voltage 1-60 kVDC; Max. Power 75 W; Efficiency >75%; Voltage Regulation <0.005% + 1 mV/mA; Current Regulation <0.1%
XP Glassman’s MK Series of 75 W high voltage AC/DC power supplies are air-insulated, fast-response, chassis-mount units with tight regulation and low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 60 kVDC.
The MK Series’ current regulation is unequalled in a module of this price range. For example, the regulation from short circuit to rated voltage for the 15 kV, 5 mA model is +2.5 µA. Overload, short circuit and arc protection is provided by automatic current regulation and by careful surge limiting design. XP Glassman’s “Air Insulated” designs are completely serviceable, these modules are not epoxy block “throw-away” power supplies.
The MK Series’ standard operation mode is constant voltage/current with less than 800 mJ of stored energy. A “multi-mode” operation mode permits maximum user flexibility. Local voltage or current control is user selectable, and the MK Series power supplies feature remote voltage and/or current control via 0 to +10 V signal or potentiometers. External interlock terminals allow enable/disable of the power supply via TTL signal.
Standard accessories for the MK Series include a detachable 2,4 m shielded output cable, mating control connector and line cord.
The MK Series supplies with 230 VAC input option (198 to 253 VAC RMS, 48 to 63 Hz) are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
Compact Module
Air Insulated
Low Ripple: <0.03% RMS of Rated Voltage + 0.5 V at Full Load
Tight Regulation
Static Voltage Regulation: <0.005% + 1 mV/mA, Line and Load
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Maximum Output Power: 75 W
Maximum Output Voltage: 1 to 60 kVDC
Maximum Output Current: 1.2 to 75 mA
Input Voltage: 105 to 125, 198 to 253 VAC RMS, 48 to 420 Hz, Single Phase
Efficiency: >75% at Full Load
Output Voltage Accuracy: 1% of Setting + 0.5% of Rated
Stored Energy: 200 mJ (10 kV Model), 1 J (50 kV Model)
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Remote Controls: DB25S D-Sub Connector and Mating Plug Provided for All Control Input Functions
Control Input Functions: +10 V Reference, External Interlock, Current Monitor, Current Program, Voltage Monitor, Voltage Program, TTL, Ground, Local Control
Options: 100, 230 VAC Input, 400 Hz Input, Control and Monitor via RS232, USB, Ethernet
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -10 to +60 °C
Dimensions: 120.6 x 131.7 x 279.4 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11404
Manufacturer:
XP Glassman
ML Series High Voltage AC/DC Power Supplies
Input Voltage 90-264 VAC; Max. Output Voltage 8-60 kVDC; Max. Power 300 W; Efficiency 85%; Voltage Regulation <0.005%; Current Regulation <0.1% of Rated Current
XP Glassman’s ML Series of 300 W high voltage AC/DC power supplies are air-insulated, fast-response, chassis-mount units with tight regulation and extremely low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 8 kVDC through 0 to 60 kVDC.
The ML Series is a family of sophisticated, medium-power, high voltage AC/DC power supplies that complies with current international safety and EMI directives. XP Glassman has packaged this series as a space-saving module to avoid the expense of front panels and displays. However, no compromises in performance and/or operating features have been made. The result is a power supply series that offers outstanding value for a wide range of demanding applications.
The ML Series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. The ML Series also features high-speed dynamic voltage regulation – for load transients of 10% to 99% and 99% to 10%, the output voltage will recover to within 1% in less than 1 ms. Ripple is less than 0.05% of rated voltage at full load, and most models exhibit less than 1 J of stored energy.
Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs, and short circuits. Current mode operation is user-configured for constant-current regulation or current-trip operation. Continuous, stable adjustment from 0 to rated voltage or current is provided by panel-mounted 10-turn potentiometer with 0.05% resolution or by external 0 to 10 V signals.
All ML Series supplies are fully RoHS compliant (2011/65/EU, Restriction of the use of hazardous substances). The ML Series supplies with 230 VAC input option (198 to 253 VAC RMS, 48 to 63 Hz) are fully compliant with the following European directives:
2014/30/EU, EMC Directive
2014/35/EU, Low Voltage Safety Directive
EN61000-3-2, Line Harmonics
Key Features:
Maximum Output Power: 300 W
Maximum Output Voltage: 8 to 60 kVDC
Compact Module
Air Insulated
Low Ripple: <0.05% RMS of Rated Voltage + 0.5 V at Full Load
Tight Regulation
Constant Voltage/Constant Current Operation
Static Voltage Regulation: <0.005% for Specified Line and Load Variations
User-selectable Automatic Current Limiting/Regulation or Current Trip Protects Against All Overload Conditions, Including Arcs and Short Circuits
PFC Option Assures Compliance with EN61000-3-2
Current Regulation: <0.1% of Rated Current From Short Circuit to Rated Voltage at Any Load Condition
Maximum Output Current: 5 to 37 mA
Input Voltage: 90 to 132, 180 to 264 VAC RMS, 48 to 420 Hz, Single Phase
Efficiency: 85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Rated Voltage
Stored Energy: 0.38 to 2.34 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Interface Control Connector: 25-pin D-Sub Miniature Connector
Control Functions: Voltage & Current Program/Monitor, HV Enable, HV Status, Safety Interlock, Current Trip/Limit Select, +10 V Reference, V/I Mode Status, Local Control
Options: 100, 230 VAC Input, Slow Start Ramp, 0 to 5 V Voltage & Current Program/Monitor, Power Factor Correction (PFC), Control and Monitor via RS232, USB, Ethernet
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +50 °C
Dimensions: 120.7 x 184.2 x 374.6/520.7 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11405
Manufacturer:
XP Glassman
MQ Series High Voltage AC/DC Power Supplies
Input Voltage 102-264 VAC; Max. Output Voltage 1-60 kVDC; Max. Power 300 W; Efficiency >85%; Voltage Regulation <0.005% + 0.5 mV/mA; Current Regulation <0.1%
XP Glassman’s MQ Series of 300 W high voltage AC/DC power supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response, chassis-mount units with tight regulation and extremely low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 60 kVDC.
The MQ Series is a family of sophisticated, medium-power, high voltage AC/DC power supplies that complies with current international safety and EMI directives. XP Glassman has packaged this series as a space-saving module to avoid the expense of front panels and displays. However, no compromises in performance and/or operating features have been made. The result is a power supply series that offers outstanding value for a wide range of demanding applications.
The MQ series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The MQ Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Ripple is less than 0.025% of rated voltage at full load. Continuous, stable adjustment from 0 to rated voltage or current by panel-mounted 10-turn potentiometer with 0.05% resolution or by external 0 to 10 V signals is provided. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor. Automatic current regulation provides protection against all overloads, including arcs and short circuits. A connection made on the interface connector allows selection of either constant-current or current-trip operation.
Standard accessories for the MQ Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable.
The MQ Series supplies with 230 VAC input option (198 to 264 VAC RMS, 48 to 63 Hz) are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
Maximum Output Power: 300 W
Maximum Output Voltage: 1 to 60 kVDC
Compact Module
Air Insulated
Low Ripple: <0.025% of Rated Voltage + 0.5 V RMS at Full Load
Tight Regulation
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
RS232, USB & Optional Ethernet Control
Static Voltage Regulation: <0.005% + 0.5 mV/mA for Specified Line and Load Variations
Dynamic Voltage Regulation: <2% of Rated Voltage
Automatic Current Regulation Protects Against All Overloads, Including Arcs and Short Circuits
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Maximum Output Current: 5 to 300 mA
Input Voltage: 102 to 132, 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 0.2% of Rated + 0.5% of Setting
Output Voltage Repeatability: <0.1% of Rated Voltage
Stored Energy: 0.35 to 3.5 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status, Fault Status, +10 V Reference, I/V Mode Status, Local Control
Options: 100, 230 VAC Input, Slow Start Ramp, Zero Start Interlock, 0 to 5 V Voltage & Current Program/Monitor, Arc Count and/or Quench, Power Factor Correction (PFC), Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 120.7 x 203.2 x 520.7 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11406
Manufacturer:
XP Glassman
OQ Series High Voltage AC/DC Power Supplies
Input Voltage 180-530 VAC 3-Phase; Max. Output Voltage 200-500 kVDC; Max. Power 8,000, 16,000 W; Efficiency 80%; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s OQ Series of high voltage AC/DC power supplies are sophisticated 8 or 16 kW open stack power supplies with extremely low ripple and noise. They are air insulated fast response units with tight regulation. A range of models is available with output voltage ranges from 0 to 200 kVDC through 0 to 500 kVDC. One master supply and up to 4 slave supplies can be run in parallel, providing a maximum of 25 to 40 kW depending on the maximum DC voltage.
OQ Series power supplies consist of a rack-style driver chassis, a high voltage stack assembly and a remote-control unit. The dimensions of the stack vary with the output voltage rating and are given in the specifications in the downloadable datasheet. The driver chassis is provided in a cabinet with 275.8 mm height x 501.7 mm width x 636.5 mm depth. The remote-control unit size is 132.5 mm height x 482.6 mm width x 186,3 mm depth.
The OQ Series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The OQ Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.1% peak-to-peak of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. The OQ Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A current-trip feature may be substituted for constant-current operation by a remote-control chassis rear panel selector switch.
Standard accessories for the OQ Series include 7.6 m of detachable interconnect cables, null modem cable and USB cable.
The OQ Series supplies are fully compliant with the following European directives:
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
Open Stack High Voltage
Maximum Output Power: 8, 16 kW – Parallelable to 40 kW
Maximum Output Voltage: 200 to 500 kVDC
Maximum Output Current: 10 to 80 mA
Low Ripple: 140 to 220 Vpp High Frequency Ripple, 20 Vpp Line Frequency Ripple
Tight Regulation
Voltage Regulation: <0.005% for Specified Line and Load Variations
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 180 to 220, 342 to 440, 370 to 460, 430 to 530 VAC RMS, 48/57 to 52/63 Hz, Three Phase
Efficiency: 80% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Setting
Maximum Stored Energy: 198 to 928 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote User Interface Terminal Strip: Voltage & Current Program/Monitor, HV Enable/Status, External Interlock, Fault Status, +10 V Reference, I/V Mode Status
Options: Zero Start Interlock, Slow Start Ramp, 0 to 5 V Voltage & Current Program/Monitor, Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: See Downloadable Datasheet
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11422
Manufacturer:
XP Glassman
OS Series High Voltage AC/DC Power Supplies
Input Voltage 198-264 VAC; Max. Output Voltage 200-450 kVDC; Max. Power 2,000 W; Efficiency 80%; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s OS Series of high voltage AC/DC power supplies are sophisticated 2 kW open stack, power supplies with extremely low ripple and noise. They are air insulated fast response units with tight regulation.
OS Series power supplies are designed to meet the growing demands from both users and electric utilities for switching supplies with excellent input power factors that draw harmonic currents below those specified in EN61000-3-2. A range of models is available with output voltage ranges from 0 to 200 kVDC through 0 to 450 kVDC.
OS Series models consist of a rack-style driver chassis, a high voltage stack assembly and a remote-control unit. The driver chassis is provided in a cabinet with 214.1 mm height x 573 mm depth, onto which the high voltage stack is mounted. The dimensions of the stack vary with the output voltage rating and are given in the specifications in the downloadable datasheet. The rack-mountable remote control provides all interface functions and is connected to the driver chassis with the 7.6 m long cables provided. The remote-control unit size is 132.5 mm height x 127 mm depth.
Active correction circuitry (power factor correction, PFC) achieves an input line current harmonic content well below the maximum specified in EN61000-3-2. The OS series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight.
Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The OS Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.05% peak-to-peak of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. The OS Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A current-trip feature may be substituted for constant-current operation by a remote-control chassis rear panel selector switch.
Standard accessories for the KT Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable.
The OS Series supplies are fully compliant with the following European directives:
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
Open Stack High Voltage
Rack-mountable Remote-control Panel
Air Insulated
Maximum Output Power: 2000 W
Maximum Output Voltage: 200 to 450 kVDC
Maximum Output Current: 3 to 10 mA
Low Ripple: 100 to 225 Vpp High Frequency Ripple, 10 to 22.5 Vpp Line Frequency Ripple
Tight Regulation
Voltage Regulation: <0.005% for Specified Line and Load Variations
Current Regulation: <±0.005% for Specified Line Variations and 0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel 10-turn Potentiometer and 0 to 10 V Remote Control
Input Voltage: 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: 80% Typical at Full Load, Power Factor >0.995
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Maximum Stored Energy: 70 to 150 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote User Interface Terminal Strip: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status
Options: Zero Start Interlock, Slow Start Ramp, 0 to 5 V Voltage & Current Program/Monitor, Control and Monitor via RS232, USB, Ethernet
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: See Downloadable Datasheet
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11415
Manufacturer:
XP Glassman
SH Series High Voltage AC/DC Power Supplies
Input Voltage 187-228 VAC 3-Phase; Max. Output Voltage 1-100 kVDC; Max. Power 8,000, 16,000 W; Efficiency 85%; Voltage Regulation <0.005%-<0.025%; Current Regulation <0.2%, <0.5%
XP Glassman’s SH Series are sophisticated 8 or 16 kW high voltage AC/DC power supplies with low ripple and noise. They are air insulated, fast response, 10U rack-mount units with tight regulation and extremely low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 100 kVDC. SH power supplies can be paralleled up to 40 kW output power, utilizing one master control module and up to four slave modules.
The SH Series features “air” as the primary dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The SH Series’ high voltage output is inhibited for a short period after each load arc to quickly extinguish the arc.
Typically, ripple is less than 0.025% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. The SH Series’ front panel contains all local control functions like AC power on/off, separate 10-turn controls to set voltage and current levels, HV voltage on and off/reset switches as well as LED indicators for high voltage on, output polarity, interlock, fault status or voltage/current regulating mode. Output levels are indicated by voltage and current digital meters.
All voltage and current programming and monitoring signals are coupled to the user interface by true differential amplifiers. This provides for the ability to return the program and monitor commons to ground or system common at the source. This arrangement isolates the return wires and eliminates errors due to unwanted return currents flowing in these connections.
The SH Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the SH Series include a remote interface mating connector, all chassis interconnection cables and a detachable 2,4 m shielded high voltage coaxial output cable. Models 16 kW and above are provided with an additional HV cable per slave module.
The SH Series supplies are fully compliant with the following European harmonized EMI directives:
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
10U Rack Mount
Air Insulated
Maximum Output Power: 8, 16 kW – Parallelable to 40 kW
Maximum Output Voltage: 1 to 100 kVDC
Maximum Output Current: 80 mA to 16.0 A
Low Ripple: <0.05% of Rated Voltage + 1 V RMS at Full Load
Tight Regulation
Voltage Regulation: <±0.005% for Specified Line and 0.01% + 10 mV/mA for Specified Load Variations, 0.025% for 80 to 100 kVDC Models
Current Regulation: <0.2% (8 to 150 kV), <0.5% (1 to 6 kV) From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 187 to 228 VAC RMS, 48 to 63 Hz, Three Phase
Efficiency: 85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Setting
Stored Energy: 8 to 80 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive, Negative or Reversible Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Differential Voltage & Current Program/Monitor, HV Enable/Status, Safety Interlock, Fault Status, +10 V Reference, I/V Mode Status
Options: Zero Start Interlock, Slow Start Ramp, 0 to 5 V Voltage & Current Program/Monitor, Blank Front Panel, Arc Count and Quench, Control and Monitor via RS232, USB, Ethernet
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 442.9 x 482.6 x 609.6 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11420
Manufacturer:
XP Glassman
WJ Series High Voltage AC/DC Power Supplies
Input Voltage 102-264 VAC; Max. Output Voltage 70-125 kVDC; Max. Power 600 W; Efficiency >85%; Voltage Regulation <0.005%; Current Regulation <0.1%
XP Glassman’s WJ Series of 600 W high voltage AC/DC power supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response, 3U rack-mount units with tight regulation and extremely low arc discharge currents. A range of models is available with output voltage ranges from 0 to 70 kVDC through 0 to 125 kVDC.
The WJ series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The WJ Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.
Typically, ripple is less than 0.1% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. Front-panel digital encoders provide high-resolution local adjustment of voltage and current program. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor.
The WJ Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds.
Standard accessories for the WJ Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable.
The WJ Series supplies with 230 VAC input option (198 to 264 VAC RMS, 48 to 63 Hz) are fully compliant with the following European directives:
EN61000-3-2, Line Harmonics
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity
2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)
Key Features:
3U Rack Mount
Air Insulated
Maximum Output Power: 600 W
Maximum Output Voltage: 70 to 125 kVDC
Maximum Output Current: 5 to 8.6 mA
Low Ripple: <0.1% of Rated Voltage at Full Load
Tight Regulation
Static Voltage Regulation: <0.005% for Specified Line and Load Variations
Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
Constant Voltage/Constant Current Operation
Arc Quench & Arc Count
Front Panel, Remote, RS232, USB & Optional Ethernet Control
Input Voltage: 102 to 132, 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase
Efficiency: >85% Typical at Full Load
Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
Output Voltage Repeatability: <0.1% of Rated Voltage
Maximum Stored Energy: 8.0 to 15.0 J
Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
Polarity: Positive or Negative Polarity With Respect to Chassis Ground
Protection: Against All Overload Conditions, Including Arcs and Short Circuits
Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status, Fault Status, +10 V Reference, I/V Mode Status
Options: 100, 230 VAC Input, Blank Front Panel, Zero Start Interlock, 0 to 5 V Voltage & Current Program/Monitor, Arc Count and/or Quench, Virtual RS-232 COM Port Over Ethernet Network
3 Year Warranty
Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
Operating Temperature: -20 to +40 °C
Dimensions: 132.5 x 482.6 x 520.7 mm
Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other
Product number:
SW11410
Manufacturer:
XP Glassman