Skip to main content

LH Open Stack Series High Voltage AC/DC Power Supplies

Product information "LH Open Stack Series High Voltage AC/DC Power Supplies"

Input Voltage 187-460 VAC 3-Phase; Max. Output Voltage 200-500 kVDC; Max. Power 4,000, 8,000 W; Efficiency 80%; Voltage Regulation <0.005%; Current Regulation <0.1%

XP Glassman’s LH Open Stack Series of high voltage AC/DC power supplies are sophisticated 4 or 8 kW open stack power supplies with extremely low ripple and noise. They are air insulated fast response units with tight regulation. A range of models is available with output voltage ranges from 0 to 200 kVDC through 0 to 500 kVDC. One master supply and up to 4 slave supplies can be run in parallel, providing a maximum of 12 to 20 kW depending on the maximum DC voltage.

LH Open Stack series power supplies consist of a rack-style driver chassis, a high voltage stack assembly and a remote-control unit. The dimensions of the stack vary with the output voltage rating and are given in the specifications in the downloadable datasheet. The driver chassis is provided in a cabinet with 231.1 mm height x 636.5 mm depth. The remote-control unit size is 132.5 mm height x 482.6 mm width x 168.3 mm depth.

The LH Open Stack Series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The LH Open Stack Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc.

Typically, ripple is less than 0.1% peak-to-peak of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. The LH Open Stack Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A current-trip feature may be substituted for constant-current operation by a remote-control chassis rear panel selector switch.

Standard accessories for the LH Open Stack Series include 7.6 m of detachable interconnect cables, null modem cable and USB cable.

The LH Open Stack Series supplies, when configured with the 400 VAC input option, are fully compliant with the following European directives:

  • EN61010/ IEC61010, Safety
  • EN61000-6-4, Conducted and Radiated Emissions
  • EN61000-6-2:2005, Conducted and Radiated Immunity
  • 2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)

Key Features:

  • Open Stack High Voltage
  • Air Insulated
  • Maximum Output Power: 4, 8 kW – Parallelable to 20 kW
  • Maximum Output Voltage: 200 to 500 kVDC
  • Maximum Output Current: 5 to 40 mA
  • Low Ripple: 100 to 160 Vpp High Frequency Ripple, 20 Vpp Line Frequency Ripple
  • Tight Regulation
  • Voltage Regulation: <0.005% for Specified Line and Load Variations
  • Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
  • Constant Voltage/Constant Current Operation
  • Arc Quench & Arc Count
  • Front Panel, Remote, RS232, USB & Optional Ethernet Control
  • Input Voltage: 180 to 220 or 340 to 460 VAC RMS, 48 to 63 Hz, Three Phase
  • Efficiency: 80% Typical at Full Load
  • Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated
  • Output Voltage Repeatability: <0.1% of Setting
  • Maximum Stored Energy: 109 to 528 J
  • Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
  • Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
  • Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
  • Protection: Against All Overload Conditions, Including Arcs and Short Circuits
  • Signals Provided on the Remote User Interface Terminal Strip: Voltage & Current Program/Monitor, HV Enable/Status, External Interlock, Fault Status, +10 V Reference, I/V Mode Status
  • Options: Zero Start Interlock, Slow Start Ramp, 0 to 5 V Voltage & Current Program/Monitor, Virtual RS-232 COM Port Over Ethernet Network
  • 3 Year Warranty
  • Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
  • Operating Temperature: -20 to +40 °C
  • Dimensions: See Downloadable Datasheet

Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other

Manufacturer "XP Power (former XP Glassman)"
XP Glassman offers a solution to most high voltage DC power supply requirements thanks to a very large standard range of high voltage power supplies and to the capability to develop and manufacture custom HV power supplies. Standard power supplies include output voltages up to 500 kVDC with output power ratings up to 200 kW, all with our 3 year warranty. XP Glassman’s DC power supplies are utilized for a broad range of applications in commercial, defence and research markets.
Related links of the manufacturer

Customers also viewed

EY Series High Voltage AC/DC Power Supplies
Input Voltage 198-264 VAC; Max. Output Voltage 1-60 kVDC; Max. Power 1,200 W; Efficiency >85%; Voltage Regulation <0.005%; Current Regulation <0.1% XP Glassman’s EY Series of 1200 W high voltage AC/DC power supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response, 2U rack-mount units with tight regulation and extremely low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 60 kVDC. The EY series features “air” as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”. The EY Series’ high voltage output is inhibited for a short period after each load arc to help extinguish the arc. Typically, ripple is less than 0.02% RMS of rated voltage at full load. Off-the-line pulse-width modulation (PWM) provides high efficiency and a reduced parts count for improved reliability. Front-panel digital encoders provide high-resolution local adjustment of voltage and current program. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor. The EY Series’ standard operation mode is constant voltage/current. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs and short circuits. A rear panel switch allows selection of either constant-current or current-trip operation. Thermostats and fan RPM sensing shut down the power supply due to over-temperature or reduced fan speeds. Standard accessories for the EY Series include a detachable 2,4 m shielded high voltage coaxial output cable, line cord, null modem cable and USB cable. The EY Series supplies are fully compliant with the following European directives: EN61000-3-2, Line Harmonics EN61010/ IEC61010, Safety EN61000-6-4, Conducted and Radiated Emissions EN61000-6-2:2005, Conducted and Radiated Immunity 2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS) Key Features: 2U Rack Mount Maximum Output Power: 1200 W Maximum Output Voltage: 1 to 60 kVDC Maximum Output Current: 20 to 1200 mA Low Ripple: <0.02% of Rated Voltage + 0.5 V RMS at Full Load Tight Regulation Static Voltage Regulation: <0.005% for Specified Line and Load Variations Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition Constant Voltage/Constant Current Operation Front Panel, Remote, RS232, USB & Optional Ethernet Control Input Voltage: 198 to 264 VAC RMS, 48 to 63 Hz, Single Phase Efficiency: >85% Typical at Full Load Output Voltage Accuracy: 0.5% of Setting + 0.2% of Rated Output Voltage Repeatability: <0.1% of Rated Voltage Maximum Stored Energy: 1.0 to 4.1 J Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h Polarity: Positive or Negative Polarity With Respect to Chassis Ground Protection: Against All Overload Conditions, Including Arcs and Short Circuits Signals Provided on the Remote Interface Connector: Safety Interlock, Voltage & Current Program/Monitor, HV Enable, HV Status, Fault Status, +10 V Reference, I/V Mode Status Options: Blank Front Panel, Zero Start Interlock, 0 to 5 V Voltage & Current Program/Monitor, Arc Count and/or Quench, Virtual RS-232 COM Port Over Ethernet Network 3 Year Warranty Approvals: IEC61010; EN61010; 2011/65/EU, Restrictions of the use of hazardous substances (RoHS); EN61000-6-4 EN61000-6-2:2005 Operating Temperature: -20 to +40 °C Dimensions: 85.7 x 431.8 x 520.7 mm Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other