Excelitas’ Axsun Swept-Source OCT Tunable Laser Engines deliver an exceptional balance of tuning bandwidth, output power, sweep speed, and coherence length—enabling cutting-edge imaging performance for medical and industrial OCT applications. Built on Axsun’s patented MEMS tunable filter and micro-optical integration platform, these lasers offer unmatched scalability and reliability. Whether for high-resolution retinal imaging, industrial defect detection, or advanced 3D ranging, Axsun lasers provide the speed and precision required for today’s most demanding OCT systems.

Key Features

  • Wide Spectral Range: Available in 1060 nm, 1220 nm, and 1310 nm configurations to support diverse OCT and NIR spectroscopy applications.
  • High-Speed Performance: Sweep rates up to 400 kHz and tuning bandwidths up to 140 nm for rapid, high-resolution imaging.
  • Exceptional Coherence Length: Measured in meters, enabling deep tissue imaging and extended ranging depth.
  • Compact & Flexible Configurations: Choose from ultra-compact OEM modules, small form factor engines, or robust benchtop enclosures.
  • Integrated Options: Supports balanced photoreceivers, k-clock outputs, data acquisition electronics, aiming lasers, and interferometers.
  • Low Power Consumption: Operates at ≤12 W typical, ideal for portable and integrated systems.
  • Proven Reliability: Telcordia-qualified components with billions of operational hours since 2001.
  • Easy Control & Diagnostics: USB interface with optional Ethernet connectivity and SDK for seamless integration.

Applications

  • Medical Imaging: High-resolution retinal and anterior segment OCT for ophthalmology.
  • Industrial Inspection: Non-destructive testing and defect identification in manufacturing processes.
  • 3D Ranging & Metrology: Wide-field imaging for precision measurement and quality control.
  • Material Analysis: Depth-resolved localization of chemical species in translucent materials.
  • Research & Development: Advanced OCT system development and experimental imaging applications.

What’s Next?

Ready to elevate your OCT system performance? Excelitas’ Axsun Swept-Source OCT Tunable Laser Engines offer unmatched speed, resolution, and reliability in a scalable platform. Contact us today to request a quote, explore customization options, or learn more about integrated features like balanced photoreceivers and data acquisition modules. With proven technology and industry-leading support, Axsun lasers are the preferred choice for next-generation OCT imaging.

Please note that Excelitas products are available from us only in Denmark, Finland, Iceland, Norway, and Sweden. 

Manufacturer "Excelitas Technologies"

Excelitas’ thermal infrared sensors like thermopiles or pyroelectric IR detectors (PIR) are used for motion detection, presence monitoring, temperature measurement and gas detection. Excelitas’ broad portfolio of sensors, detectors and emitters also includes phototransistors, photodiodes, PIN photodiodes, avalanche photodiodes (APD), ambient light sensors, single photon detectors and many more.


The products can be found in a vast array of applications across automotive, consumer products, defense and aerospace, industrial, medical, safety and security and sciences sectors.


Please note that Excelitas products are available from us only in Denmark, Finland, Iceland, Norway, and Sweden. 

Related links of the manufacturer
Information on the manufacturer (information obligations under the GPSR Product Safety Regulation)
Excelitas Technologies GmbH + Co. KG
Wenzel-Jaksch-Strasse 31
65199 Wiesbaden, Germany

Customers also viewed

Swept Light Sources
Littman-Metcalf Configuration; Center Wavelength 1310 to 1330 nm; Wavelength Span >100 nm; Energy ≥17 mW; Coherence Length >7 mmNTT Advanced Technology Corporation’s 200 kHz swept light source for OCT imaging is currently the highest speed swept-wavelength light source in the world. Emitting wavelengths in the 1.3 μm band, the swept light source is ideally suited for OCT-based examination of the coronary arteries.The device accelerates image acquisition and as a result reduces diagnosis time. This reduction in diagnosis time contributes to a great reduction of both the physical and the psychological impact on patients.The total system cost can be reduced because the load on the image processing system is reduced and the linear frequency sweeping enables easy calculation of the relationship between time and wavelength.The swept-wavelength light source with a KTN deflector is aiming at the usage in phase sensitive OCT systems (Doppler OCT and PS OCT: applications to new OCT diagnosis methods) because of its lower jitter than that of the more generally used MEMS-based light sources.Core building block of the wavelength swept light source is a laser with an external resonator, the so-called Littman-Metcalf configuration. By optimizing the laser with a highly efficient diffraction grating and KTN light deflectors into a compact structure, high-speed operation, a wider wavelength sweep span, and sufficient coherence length are realized.Key Features:High Speed (200 kHz Sweep Rate)Voltage-controlled Sweeping Formats (k-linear scan available)High Phase Stability (Low Trigger Jitter <78 ps)Coherence Length 7 mm at 200 kHz ScanHigh Reliability (No Moving Parts)Wavelength Sweep Span >100 nmAverage Light Output ≥17 mWApplications: OCT Imaging
Product number: SW10559

REQUEST PRICING AND AVAILABILITY

- Get your individual quote.
- Technical compatibility review included.
- Volume discounts available.

No obligation. Direct access to our engineering team.