Skip to main content

POD 2000 High-Speed Polarimeter

Product information "POD 2000 High-Speed Polarimeter"

Wavelenght Range (C-band version) 1500 – 1600 nm, 1550 nm typical; Wavelength Range (O-band version) 1260 – 1360 nm; 1310 nm typical; Dynamic Range -45 – 5 dB; SOP Uncertainty @ Calibration Wavelength 1.5°, Azimuth 1°, Ellipticity 1°; DOP uncertainty @ Calibration Wavelength -1.5% - 1.5%; Measurement Update Rate 100KHz; Measurement SOP Entire Poincaré Sphere

Luna’s POD 2000 is a DSP-powered polarimeter designed for high-speed polarization characterization, analysis, and monitoring. It utilizes four channels to simultaneously capture the four Stokes parameters, allowing it to measure an input light beam’s instantaneous state of polarization (SOP) and degree of polarization (DOP).

With a USB 2.0 interface, data can be directly transferred to a computer, enabling the polarimeter to monitor and analyze rapid polarization changes at a sampling rate of up to 100 KS/s. Additionally, it supports standard 100BASE-TX Ethernet for measurement and control.

The POD 2000 features a user interface that provides real-time graphical displays of the polarization state. This can be viewed on a Poincaré Sphere window for SOP traces or on an oscilloscope window for tracking polarization changes over time.

Key features:

  • High speed, SOP/DOP measurement with 100Khz date update rate
  • High accuracy
  • Dynamic range -45 to 5 dBm
  • None Stop or Continuous measurement as high as 100KHz update rate.
  • USB 2.0, Ethernet 100BASE-TX
  • SCIP command, C/C++ API, PC GUI
  • Trigger in/out

Applications: SOP/DOP monitoring, Polarization analysis, Scrambler DOP characterization, SOP statistics, PM fiber alignment to light sources, Polarization extinction ratio Analysis

Manufacturer "Luna"
Headquartered in Roanoke, VA, USA, Luna develops, manufactures and markets high-definition fiber optic sensing products and fiber optic test and measurement instrumentation . Luna's products are used to measure, monitor, protect and improve critical processes in the healthcare, telecommunications, energy and defense markets. Luna has become a recognized leader in transitioning science to solutions. Luna’s high-definition fiber optic sensing technology allows engineers to test, modify and qualify their designs; efficiently, effectively, and accurately. The HYPERION series of fiber optic sensing interrogators provide many of the advantages of fiber optic systems and distinguishes itself by virtue of high spatial resolution. On the test and measurement side, Luna provides diagnostic and test instrumentation that enables the complete characterization of optical components, assemblies and short-haul networks; providing substantial cost and time savings in the development, production, and maintenance of optical network equipment. Optical backscatter reflectometers (OBR series) enable ultra-high resolution reflectometry with backscatter level sensitivity, while lightwave component and optical vector analyzers extend Luna’s industry-leading optical frequency domain reflectometry (OFDR) platform to manufacturing test and quality control applications for passive optical components.
Related links of the manufacturer
Information on the manufacturer (information obligations under the GPSR Product Safety Regulation)
Luna Innovations, Inc.
301 1st Street SW, Suite 200
VA 24011 Roanoke, United States

Customers also viewed

POD Polarimeter
1310, 1550 nm; IL ≤1.2 dB; PDL <0.25 dB; PMD <0.1 ps; WDL 0.15 dB; RL 55 dBLunas’ POD module is an in-line polarimeter for low-cost, high-speed polarization characterization without interrupting data traffic. It outputs four voltage signals for calculating in microseconds both the degree of polarization (DOP) and the state of polarization (SOP) of the light passing through the device.The POD polarimeter module comes with a preamplification board to provide analog signals for SOP/DOP calculation, feedback control, and computer interface. A calibration matrix is provided with every device for the calculation. Devices without preamplification board and calibration matrix are also available for OEM applications.The POD polarimeter module is ideal for integration into polarization monitoring and polarization stabilization modules, or in polarization characterization instruments. Key Features:High Speed – Measurement Bandwidth: 50 kHz (With Preamplifier Board), 1.5 MHz (Optical Head Alone)Low Insertion Loss (IL): 0.8 dB Typical, 1.2 dB MaximumReturn Loss: 55 dBPolarization Dependent Loss (PDL): <0.25 dB Polarization Mode Dispersion (PMD): <0.1 ps Wavelength Dependent Loss (WDL): 0.15 dBOptical Power Sensitivity: 5 µWOptical Power Handling: 5 mWWavelength Range: 1310, 1550 nmCompact Size – Dimensions: 37 x 20 x 15 mm, 125 x 50 x 16.5 mm (With Preamplifier Board)No Moving Parts Applications: Integration Into Polarization Monitoring and Polarization Stabilization Systems; Integration With Polarization Characterization Systems
Product number: SW11290

REQUEST PRICING AND AVAILABILITY

- Get your individual quote.
- Technical compatibility review included.
- Volume discounts available.

No obligation. Direct access to our engineering team.