Skip to main content

AvaLight-DHc Full Range Light Source

Product information "AvaLight-DHc Full Range Light Source"

Deuterium-Halogen; 200-2500 nm; Stability <1 mAU; Drift <0.25%/h; Optical Power 0.2, 7 µW; Power Supply 12 VDC, 450 mA

Get the best of two worlds with Avantes’ AvaLight-DHc full range light source. It has both a deuterium light source and a halogen light source, providing you with adequate light between 200 and 2500 nm for nearly all absorbance chemistry applications. Deuterium emits light between 200 and 550 nm, whereas halogen emits light of up to 2500 nm.

Coupling to the rest of your spectroscopy system is easy with the SMA connector. This light source is recommended in settings with large fiber cables or direct-attachment to a cuvette holder such as the CUV-DA, due to its relatively low output energy. The integrated TTL-shutter makes saving a dark measurement very simple in combination with AvaSoft (extra IC-DB26-2 needed).

Optionally, the AvaLight-DHc is available in a rack-mountable version, to be used in the 19” rack or the 9.5” desktop system. A direct-attach cuvette holder CUV-DA is available for fluorescence or absorbance measurements.

Key Features:

  • Combined Deuterium-Halogen Light Source
  • Integrated TTL-Shutter
  • Wavelength Range: 200 to 2500 nm
  • Stability: <1 mAU
  • Warm-up Time: 1, 8 min
  • Drift: <0.25%/h
  • Optical Power (in 600 µm Fiber): 0.2, 7 µW
  • Lamp Lifetime: 1000, 2000 h
  • Temperature Range: 5 to 35 °C
  • Power Supply: 12 VDC, 450 mA
  • Dimensions: 175 x 110 x 44 mm

Applications: Nearly All Absorbance Chemistry Applications

Manufacturer "Avantes"
Avantes is a leading innovator in the development of fiber-optic spectroscopy instruments and systems with 25 years of experience developing customer-defined spectrometer solutions. With a long history of consulting with clients across diverse industries and applications, Avantes is an experienced partner, equipped to guide customers who want a solution tailored to their application and research needs. Countries of Representation Denmark, Iceland, Norway, Sweden
Related links of the manufacturer

Customers also viewed

1.25A Laser Diode Driver PCB Mount - PLD1250
The PLD Series Laser Diode Drivers deliver the reliability and performance you expect from a Wavelength Electronics laser driver in a compact and easy-to-integrate package. Tens of thousands of PLD drivers are deployed in particle counters, manufacturing vision systems, wavefront scanners, fiber aligners, and other laser systems around the world, proving beyond doubt the reliability and stability of the design. The PLD drivers operate from a single 5 V power supply. To accommodate high compliance lasers, or multiple stacked lasers, the PLD laser diode drivers allow the laser to be driven from a separate power supply up to 30 V. Key Features Models: 200 mA, 500 mA, 1.25 A, 5 A, and 6.5 A Operates from a 5 VDC supply Separate power supply can be used to drive high-compliance lasers up to 28 V Constant Current or Constant Power modes Safety features protect your laserAdjustable latching current limitSlow-start circuitryRelay shorts output when current is disabled Local and Remote Power-On and Enable controls Integral heatsink and fan on high current model
Product number: C019341-6
Manufacturer:

€529.48*
Transmission Probes
Wavelength range 200-2500 nm; Pressure Probe Head 10 bar @ 25°C; Connector Type SMA-905Transmission dip probes are designed for on-line and inline absorbance measurements in fluids. By dipping or permanently mounting the probe end into the fluid, absorbance can be measured. Explore our range of transmission dip probes below.Transmission ProbesTransmission dip probes are used for on-line and inline absorbance measurements in fluids. By dipping or permanently mounting the probe end into the fluid, absorbance can be measured. A standard SMA-905 connector couples light into a fiber bundle, typically consisting of six fibers (other configurations available upon request). The light is transmitted to the probe end, where it crosses a predetermined gap and is reflected against a diffuse white reflective material back onto the receiving read fiber, which is coupled to a spectrometer on the second leg of the probe. The read fiber is centrally placed within the illumination fiber bundle to provide optimal collection efficiency. Both bundles are housed in flexible stainless steel jacketing, and the probe tip is also made of stainless steel. At the mid-point of the assembly, a ferrule splits the fibers into their respective legs (illumination and read), which are terminated in SMA-905 connectors.Mini Transmission ProbesFor absorption measurements in miniaturized centrifuge tubes or vessels, Avantes offers the mini transmission dip probe. It features a miniaturized tip that is 130mm long and 3.2mm in diameter. The mini transmission dip probe has a fixed optical path length of 5 or 10 mm. It is available in three versions: one for UV/VIS (200-800 nm) measurements, one for VIS/NIR (350-2500 nm), and one for UV/VIS/NIR (250-2500 nm). For best results below 240 nm, solarization-resistant fiber (-SR) is recommended. The probe features Avantes ME, chrome-plated brass, and jacketing. Optionally, the probe can be configured with a longer stainless steel or Hastelloy® tip or other jacketing options (MS, BX, or PVC). It has two SMA connectors (FC/PC also available) for convenient coupling to the Avantes line of spectrometers and light sources.Mini Transmission Dip Probes with Variable Path LengthThis fiber-optic probe features a variable and adjustable path length for more flexibility during absorbance measurements in fluids. The gap between the fiber and the diffuser can be set anywhere between 0.25 and 10 mm. A standard SMA-905 connector couples light into a fiber bundle, typically consisting of six fibers (other configurations available upon request). The light is transmitted to the probe end, where it crosses the predetermined gap and is reflected against a diffuse white reflective material back onto the receiving read fiber, which is coupled to a spectrometer on the second leg of the probe. The read fiber is centrally placed within the illumination fiber bundle to provide optimal collection efficiency. Both bundles are housed in flexible stainless steel jacketing, and the probe tip is also made of stainless steel. At the mid-point of the assembly, a ferrule splits the fibers into their respective legs (illumination and read), which are terminated in SMA-905 connectors.Applications: On-line and in-line absorbance measurements in fluids
Product number: SW12010
Manufacturer:

€0.00*