International Light Technologies
ILT 770 UV Light Meter Series
Wavelength 215-401 nm; ISO/IEC 17025:2017 Accredited; NIST traceable calibrationThe ILT770 is a compact, handheld UV light meter that’s loaded with features. It’s designed for use in a phototherapy booth and comes with built-in data storage, a rechargeable lithium ION battery, and a user-friendly display that shows both numerical and graphical readings. This allows for easy analysis of the system and generation of reports. The units of readout include both Irradiance in W/cm2 and dose in J/cm2, with auto-ranging capabilities (uw/cm2, mW/cm2 uJ/cm2, mJ/cm2, J/cm2 etc).The ILT770 UV light meter is available in five standard configurations:ILT770-UV: 215-350 nmILT770-NB: 249-259 nmILT770-NBUVB311: 275-325 nmILT770-UVA-350: 315-390 nmILT770-UVA-1: 326-401 nmEach package includes an ILT770 light meter, a UV sensor (options include UVC, Narrow band UVC, Narrow band UVB, UVA or UVA-1), a NIST traceable – ISO17025 accredited calibration with certificate, a storage case, a USB cable, PC software for downloading stored readings, and a 1-year warranty. This is a comprehensive solution for your UV measurement needs.Key features: SO/IEC 17025:2017 Accredited, NIST traceable calibration for results you can trust Measures irradiance and doseGraphical display with data analysisAffordableStores readings that can be downloaded to a PC Compact, portable ergonomic designRechargeable battery Create reports with downloaded data Easy-to-use interface Made in the USA BNC connector locks sensor in placeLinear over 4 decades of light levelsApplications: Validation of UV disinfection systems; testing of UVA and narrow-band UVB sources, e.g. for skin treatmentPlease note that International Light products are available from us only in Denmark, Finland, Iceland, Italy, Norway, and Sweden.
Product number:
SW11993
Manufacturer:
International Light Technologies
REQUEST PRICING AND AVAILABILITY
- Get your individual quote.
- Technical compatibility review included.
- Volume discounts available.
No obligation. Direct access to our engineering team.
ILT2400 Handheld Light Meter and Optometer Series
Measurement Range: > 10 Decades 100 fA - 1 mA - (1 n/Wcm2 to 10 W/cm2); Datalogging Memory 16,380 total light level readings; Operating Temperature -40 - +85°CThe ILT2400 stands out as the market’s most advanced hand-held light/lux meter and optometer. It comes equipped with ILT’s Accuspan software, which automatically sets the averaging while swiftly measuring over eight decades of light intensities. The built-in software enables customers to capture a peak as brief as 100μS and store up to 16 readings per second. The color display is versatile, functioning in both landscape and portrait modes.ILT, based in Peabody, MA, USA, manufactures the ILT2400 and its software. This allows ILT to quickly configure and customize components to meet the needs of customers and OEMs.The ILT2400 optical measurement systems package includes an ILT2400 device, carrying case, software, and a detector/filter/optic and calibration configured to the customer’s needs. The ILT2400 optical measurement systems enable direct reading in the relevant empirical units, including lux, foot-candles, candela, lumens, watts, W/cm2, cd/m2, foot-lamberts, nits, etc. The ILT2400 and its software are compatible with most computers running Windows 7 and Windows 8.Key features: Research Quality at a Hand-held Price8 Decade Dynamic Range of Optical AnalysisMeter & Sensors with NIST Traceable ISO17025 Accredited CalibrationHand-held, Compact, Ergonomic DesignBrilliant 4.3” Touch Screen Display90° Screen Rotation for Landscape and Portrait ViewingILT’s Accuspan: Auto-ranging with Smart AveragingBuilt-in Rechargeable Battery Lasts Up to 8 HoursBackwards Compatible with ILT1700 SensorsMeasurement Speeds Up to 100 μSecondsIncludes DataLight III comprehensive software package for both Mac and PC Made in the USAApplications: Audience Scanning Laser Safety, General Purpose Light Measurements, Research, Sterilization/UVGI, Solar Measurements, Photoresist/Lithography, Optical Radiation Hazard, Phototherapy, Photo-Degradation, PPF & PPFD Plant Studies, and more.Please note that International Light products are available from us only in Denmark, Finland, Iceland, Italy, Norway, and Sweden.
Product number:
SW11996
Manufacturer:
International Light Technologies
REQUEST PRICING AND AVAILABILITY
- Get your individual quote.
- Technical compatibility review included.
- Volume discounts available.
No obligation. Direct access to our engineering team.
ILT5000 Research Lab Radiometer International Light
Measurement Range 100 fA - 1 mA; Reverse Bias 2 Voltages/Selectable; Operating Temperature -40 - +85 °C; Calibrated Irradiance 0 - 40 °CThe ILT5000 radiometer is the ILT1700 for the 21st Century! Improvements on the industry standard ILT1700 include rapid optical measurements (1-100hz), a broader dynamic range (100fA to 1mA), Datalight III for PC and Mac, plus built-in wireless, data storage, and rechargeable batteries.The ILT5000 is backwards compatible with the ILT1700 sensor configurations, as well as all of ILT's sensor accessories including filters, optics, integrating spheres and ISO/IEC 17025:2017 Accredited/NIST traceable calibrations.ILT manufactures the ILT5000 and DataLight III radiometer in the USA at our Peabody, MA facility which allows us to rapidly customize system components to meet the needs of our customers and OEMs.ILT5000 optical measurement systems typically consist of the ILT5000 light meter, a sensor, filter, optic and calibration to allow direct reading in the appropriate empirical units including lux, foot-candles, candela, lumens, watts, W/cm2, cd/m2, foot-lamberts, nits, etc.Measurement systems: The ILT5000 meter requires a sensor to measure light. Sensors are available to measure from 185 nm out to 40 micron and are supported with a vast array of accessory including bandpass filter, cosine receptors, integrating sphere, and numerous types of calibration.Key Features:Measurement Range: Over 10 Decades 100 fA - 1 mA- (1 n/Wcm2 to 10 W/cm2)Datalogging Memory: Can store 16,380 total light level readings or 8,190 light level with real time stamp(At one reading per minute, this equates to 11.3 days (real time stamp off) or 5.6 days of logging with time stamp on)Built-in Wi-FiOperating Temperature: -40 to 85° C (Calibrated Irradiance: 0-50° C)USB: USB2, Including Power, for Single and Multiple SystemsUSB Current Draw: 500 mA max., 250 mA typicalSize: 1-3/5" H x 5" W x 7" LInput Connector: D-Sub and SMACE Certified: No rf noiseCalibration: NIST Traceable/ISO 170254 - 20 mA outputSample rate up to 100 Hz, programmableAuto-range, Auto-dark, Auto-sample with user control optionsBuilt-in rechargeable battery pack"Set it & Forget it" remote data loggingContinuous multi-system monitoringBackward compatible with the ILT1700 SED detector/filter/opticsLabview compatibleNIST Traceable / ISO/IEC 17025:2017 Accredited calibration and certificateIncludes DataLight III comprehensive software package for both Mac and PCComes with ILT's DataLight III Software includedDataLight is all about supplying fast, reliable light measurement data to you computer for analysis. Our extensive light measurement software package is available for Windows PC, Tablet and MAC computers.DataLight III includes our "set it and forget it" remote internal data storage app., an improved All-in-One meters app for control and transmission of data using a mini USB cable or wireless data transmission, as well as a full API and command line interface for user programming and customization.Applications: Radiometry, Photometry, Reasearch, UVGI- Sterilization, Solar, Photoresist, Optical Radiation Hazard, Phototherapy, Photo-degradation, Plant Growth and morePlease note that International Light products are available from us only in Denmark, Finland, Iceland, Italy, Norway, and Sweden.
Product number:
SW11997
Manufacturer:
International Light Technologies
REQUEST PRICING AND AVAILABILITY
- Get your individual quote.
- Technical compatibility review included.
- Volume discounts available.
No obligation. Direct access to our engineering team.
ILT560 Miniature Spectrometer Spectroradiometer
Measurement Range: 350-900 nm Standard, 250-900 nm with upgrade; NIST-traceable calibration; Stray Light <0.1% @600, 435 nm; Integration Time 0.5ms - 10 secondsThe ILT560 is a miniature, portable spectrometer series for budget-conscious customers. The ILT560 Spectroradiometer comes standard with a SMA905 receptor allowing it to be used a variety of fiber patch cords including both flexible and rigid models. All systems include ILT's comprehensive software package, SpectriLight II, to allow calculations such as CCT.Key features:Range: 350 nm to 900 nm Standard (250-900 nm requires RAA4 and dual source calibration upgrade)NIST-Traceable Calibration IncludedSpectral Range 350-900 nm standard, 250-900 nm with upgradeStray Light: <0.1% @600, 435 nmAD Converter: 16 bit, 2 MHzSignal/Noise: 600:1Integration Time: 0.5 ms – 10 secondsInterface: USB 2.0Power Suppl:y USB PowerDimensions: 91 x 60 x 34.5 mmTemperature Range: 5 – 35 °CCCD: 2048Resolution: 1 nmSlit: 25 micronApplications: Plant Growth/PAR/Plant Photobiology, Characterization of UV Curing Systems, Photostability Testing, Reflectance, Absorbance/Transmittance, LED Illumination and Color Analysis, Radiometery and Photometry Measurements, AcceleratedPlease note that International Light products are available from us only in Denmark, Finland, Iceland, Italy, Norway, and Sweden.
Product number:
SW11999
Manufacturer:
International Light Technologies
REQUEST PRICING AND AVAILABILITY
- Get your individual quote.
- Technical compatibility review included.
- Volume discounts available.
No obligation. Direct access to our engineering team.
ILT750 Bili Light Meter Series
Wavelength 420-520 nm; Band Irradiance Range .08 to 8000 µW/cm2/nm; Irradiance Range 3 to 300,000 µW/cm2; Current Range 1 nA to 1.65 uAThe ILT750 Bili Light Meter is available in two configurations:ILT750 Bili Light Meter – 470 nm ILT750 Bili454 Light Meter – 454 nm, direct substitute for the Ohmeda Light Meter The ILT750 Bili Light Meter is a comprehensive solution for measuring light in neonatal jaundice treatment systems. This bilirubin light meter eliminates the need for manual recording and calculation of multiple measurements to obtain your irradiance value. Simply move the ILT750 detector over the blanket or under the light source and let the meter calculate for you.Key features:Dual units with a wide sensitivity range: from .08 to 8000 µW/cm2/nm, and 3.0 to 300,000 µW/cm2User-friendly device3-digit display resolutionPeak response at 470 nm, aligning with the bilirubin action spectrumCalibration that is ISO/IEC 17025:2017 Accredited and NIST TraceableSensor corrected for cosine for accurate spatial responseMeasures Band Irradiance (µW/cm2/nm) or Irradiance (W/cm2)Compatible with traditional and LED sourcesSuitable for bili blankets, pads, or overhead lampsHousing that is easy to cleanCompact and ergonomic design that is easy to holdPowered by AA batteriesMade in the USA The ILT750-BILI454 Light Meter serves as a direct substitute for the Ohmeda light meter, designed to test both traditional and LED blue light sources from GE, which are used in the treatment of neonatal jaundice. The advanced capabilities of the ILT model remove the need for manual calculations or note-taking. Simply move the detector across the blanket or beneath the light source, and the meter will handle the calculations for you.After rigorous design and testing, the ILT750-BILI454 meter can read within a few percentage points of the discontinued Ohmeda Biliblanket II Blue light meter. This meter is versatile and can be used not only on the blanket but also on all GE lighting systems, including:GE Giraffe SystemsGE Lullaby SystemsGE BiliSoft SystemsTraditional GE Blue light systemsKey features:Measures within a few percentages of the discontinued Ohmeda meterFeatures a large, easy-to-read OLED displayCalibrated at 454 nm using a GE LED light sourceCan verify and average irradiance values across the entire treatment area in less than a minuteCalibration is ISO/IEC 17025:2017 Accredited and NIST TraceableAllows selection of units (µW/cm2/nm or W/cm2)Designed with an easy-to-hold, lightweight, and ergonomic design that’s easy to cleanCustom filter matching is designed into the deviceMade in the USAApplications: testing of GE traditional and LED blue light sources for treatment of infant jaundicePlease note that International Light products are available from us only in Denmark, Finland, Iceland, Italy, Norway, and Sweden.
Product number:
SW11994
Manufacturer:
International Light Technologies
REQUEST PRICING AND AVAILABILITY
- Get your individual quote.
- Technical compatibility review included.
- Volume discounts available.
No obligation. Direct access to our engineering team.
ILT800 CureRight Radiometer Series
Wavelength 215-475 nm; Range 4.5 decade (mW/cm2 to 40W/cm2); Temperature 0-75 °C (internal case temperature)The ILT800 CureRight is a UV curing radiometer that is packed with features, offering unparalleled flexibility and capabilities not found in any other system. Its adaptability enables the device to measure lights used for UV curing and a variety of other applications such as sterilization/disinfection, lithography, and more. The system is designed with the diverse needs of its users in mind and can be tailored to fit your specific environment.The ILT800 CureRight series validates and measures all kinds of UV curing methods and sources, including conveyor, belt, oven, flood, area, spot, fiber optic, collimated beam, side cure, 180° curing, 3D printing, pulsed and traditional UV lamps, and UV/VIS LEDs & light sources.The ILT CureRight is available in five standard configurations:ILT800-UVA: 315 - 390 nmILT800-BAV: 275 - 475 nmILT800-UV: 250 - 400 nmILT800-CUV: 215 - 350 nmILT800-UVF (UV LED): 360 - 400 nm Flat, (275 - 450 nm)Contact us for OEM / Custom FiltrationThe ILT800 CureRight UV radiometer system surpasses competitors with features like standard profiling and programmable settings such as measurement modes (auto/manual/live), minimum light level threshold, and lamp-to-lamp measurement interval (delay). The system also boasts a unique user interface that places the input sensor and optic, device controls, and the readout display all on one side, facilitating simultaneous measurement, monitoring, and analysis of measurement data.The ILT800 UV radiometer allows users to track their curing processes over time by allowing them to store, download, and view both current and all previously saved readings on the device’s integrated OLED display. This built-in data storage and review feature enables users to quickly identify changes that have occurred over time. It also helps users to easily spot potential issues in their systems such as dirty lamps and reflectors, lamp/reflector misalignment, declining lamp output, failed lamps, and power supply problems, among others. Additional benefits include the ability to download the results to a computer for more detailed analysis. With ILT’s proprietary DataLight CureRight software interface, users can download and view their data, as well as generate spreadsheets and reports using their own analysis tools.To further enhance the data storage and capabilities, ILT introduced an advanced sorting feature called Device ID, a feature not found in any other UV curing light meter. Device ID allows users to program up to 20 unique system/light source name tags. Device ID enables users to view and export all saved data for each curing station or light source into separate files, clearly identified with the Device ID. It’s like having the functionality of multiple meters in a single device.The ILT800’s spectral filtration was designed to match the photoinitiators’ response to UV light, which is directly related to its absorption and is highly wavelength selective. Most lamps emit broadband UV/VIS/IR, and the lamp’s output may not change evenly across all wavelengths. The ILT800 filters were designed to monitor changes in output in the areas that affect absorption, and consequently, the effectiveness of the curing. Whether you’re using a low-output fluorescent source for sterilization, high-intensity mercury or xenon lamps for curing, or narrow-band LEDs for photolithography, there’s a version of the ILT800 tailored for your needs.Filtration options covering UVC to UV-VISFiltration to ensure a process matchMeasures only the light that effects the cureApplications: low-output fluorescent sources for sterilization, high-intensity mercury or xenon lamps for curing, narrow-band LEDs for photolithographyPlease note that International Light products are available from us only in Denmark, Finland, Iceland, Italy, Norway, and Sweden.
Product number:
SW11995
Manufacturer:
International Light Technologies
REQUEST PRICING AND AVAILABILITY
- Get your individual quote.
- Technical compatibility review included.
- Volume discounts available.
No obligation. Direct access to our engineering team.